Ultrasonic anechoic chamber qualification: accounting for atmospheric absorption and transducer directivity.
نویسندگان
چکیده
Qualifying an anechoic chamber for frequencies that extend into the ultrasonic range is necessary for research work involving airborne ultrasonic sound. The ANSI S12.55/ISO 3745 standard which covers anechoic chamber qualification does not extend into the ultrasonic frequency range, nor have issues pertinent to this frequency range been fully discussed in the literature. An increasing number of technologies employ ultrasound; hence the need for an ultrasonic anechoic chamber. This paper will specifically discuss the need to account for atmospheric absorption and issues pertaining to source transducer directivity by presenting some results for qualification of a chamber at Brigham Young University.
منابع مشابه
تحلیل آکوستیکی یک اتاق نیمه صامت با چینش متقاطع جاذب الیافی مکعب مستطیل
Introduction: The previous studies have used fibrous absorbents usually in the form of cone-shaped wedges for making anechoic and semi-anechoic chambers which their design and construction have been costly and difficult. The present study aimed to design a semi-anechoic chamber, using rectangular fibrous absorbents and also perform acoustic analysis for it. . Material and Method: In the presen...
متن کاملDesign and Performance Analysis of Capacitive Micromachined Ultrasonic Transducer Linear Array
An ultrasonic transducer is a key component to achieve ultrasonic imaging. This paper designs a new type of Microelectromechanical Systems (MEMS) based capacitive ultrasonic transducer and a linear array based on the transducer. Through directivity analysis, it can be found that its directivity is weak due to the small size of the designed transducer, but the directivity of the designed linear ...
متن کاملA Highly-directional Ultrasonic Range Sensor Using a Stepped-plate Transducer
A new type of highly-directional ultrasonic range sensor is designed, fabricated, and tested in this paper. To improve directivity, the parametric acoustic array, a nonlinear effect of media between two intensive waves, is applied to an ultrasonic range sensor. Additionally, a new type of the stepped-plate transducer is applied for generating high amplitude waves consisting of two frequencies. ...
متن کاملDirectivity Pattern Measurement of Ultrasound Transducers
Both diagnostic and therapeutic ultrasound applications require an understanding of the directivity patterns on the transducers to design ultrasound equipment and faithfully characterize the acoustic output from medical ultrasound devices. Since each ultrasound transducer has its own specific directivity pattern, the measurement of the directivity pattern is necessary. The objectives of this wo...
متن کاملTonehole Radiation Directivity: A Comparison of Theory to Measurements
Measurements have been conducted in an anechoic chamber for comparison to current linear acoustic theory for radiation directivity from a cylindrical pipe with toneholes. Time-delay spectrometry using an exponentially swept sine signal was employed to determine impulse responses at points external to the experimental air column. This technique is effective in clearly isolating nonlinear artifac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 130 2 شماره
صفحات -
تاریخ انتشار 2011