In vitro effects on platelets irradiated with short-wave ultraviolet light without any additional photoactive reagent using the THERAFLEX UV-Platelets method.

نویسندگان

  • P Sandgren
  • F Tolksdorf
  • W G Struff
  • H Gulliksson
چکیده

BACKGROUND A novel short-wave ultraviolet light (UVC) pathogen reduction technology (THERAFLEX UV-Platelets; MacoPharma, Mouvaux, France) without the need of any additional photoactive reagent has recently been evaluated for various bacteria and virus infectivity assays. The use of UVC alone has on the one hand been shown to reduce pathogens but may, on the other hand, have some impact on the platelet (PLT) quality. The purpose of this study was to determine the potential effects on PLT quality of pathogen inactivation treatment using the novel UVC method for PLT concentrates. STUDY DESIGN AND METHODS Buffy-coat-derived PLTs suspended in SSP+ were irradiated with UVC light in plastic bags (MacoPharma) made of ethyl vinyl acetate, considered to be highly permeable to UVC light. The UVC-treated (test, n=8) as well as the untreated (reference, n=8) PLT units were stored in PLT storage bags composed of n-butyryl, tri n-hexyl citrate-plasticized polyvinyl chloride (MacoPharma) on a flat bed agitator for in vitro testing during 7 days of storage. RESULTS No significant difference in PLT counts and lactate dehydrogenase between the groups was detected. During storage, glucose decreased more and lactate increased more in the test units. Statistically significant differences were found for glucose (P<0·01) and lactate (P<0·05) on day 7. ATP levels were higher (P<0·01 from day 5) in the reference units. With exception of day 7 (P<0·01 reference vs. test), hypotonic shock response reactivity was not different between groups. Extent of shape change was lower (P<0·01), and CD62P (P<0·05 day 5) was higher in the test units. CD42b and CD41/61 showed similar trends throughout storage, without any significant difference between the units. pH was maintained at >6·8 (day 7) and swirling remained at the highest level (score = 2) for all units throughout storage. CONCLUSION Our results suggest that irradiation with UVC light has a slight impact on PLT in vitro quality and appears to be insignificant with regard to current in vitro standards.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro Quality of Platelets with Low Plasma Carryover Treated with Ultraviolet C Light for Pathogen Inactivation.

BACKGROUND The THERAFLEX UV-Platelets system uses shortwave ultraviolet C light (UVC, 254 nm) to inactivate pathogens in platelet components. Plasma carryover influences pathogen inactivation and platelet quality following treatment. The plasma carryover in the standard platelets produced by our institution are below the intended specification (<30%). METHODS A pool and split study was carrie...

متن کامل

Potatoes: Source of Laboratory Reagent for Human Platelets Research

Irish potatoes is rich in carbohydrate, with varied glucose levels. It is also a very good source of apyrase, an enzyme used for platelet storage. The aim of this study was to explore Irish potatoes as an easily available source for apyrase extraction and purification. Apyrase was extracted from 5 Kg of Irish potatoes. Platelets were derived from 5-10 ml of human whole blood and G6PD activity w...

متن کامل

Ultraviolet C light pathogen inactivation treatment of platelet concentrates preserves integrin activation but affects thrombus formation kinetics on collagen in vitro.

BACKGROUND Ultraviolet (UV) light illumination in the presence of exogenously added photosensitizers has been used to inactivate pathogens in platelet (PLT) concentrates for some time. The THERAFLEX UV-C system, however, illuminates PLT concentrates with UV-C light without additional photoactive compounds. In this study residual PLT function is measured in a comprehensive paired analysis of UV-...

متن کامل

Pathogen reduction through additive-free short-wave UV light irradiation retains the optimal efficacy of human platelet lysate for the expansion of human bone marrow mesenchymal stem cells

BACKGROUND We recently developed and characterized a standardized and clinical grade human Platelet Lysate (hPL) that constitutes an advantageous substitute for fetal bovine serum (FBS) for human mesenchymal stem cell (hMSC) expansion required in cell therapy procedures, avoiding xenogenic risks (virological and immunological) and ethical issues. Because of the progressive use of pathogen-reduc...

متن کامل

In Vitro and In Vivo Characterization of Ultraviolet Light C-Irradiated Human Platelets in a 2 Event Mouse Model of Transfusion

UV-based pathogen reduction technologies have been developed in recent years to inactivate pathogens and contaminating leukocytes in platelet transfusion products in order to prevent transfusion-transmitted infections and alloimmunization. UVC-based technology differs from UVA or UVB-based technologies in that it uses a specific wavelength at 254 nm without the addition of any photosensitizers....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vox sanguinis

دوره 101 1  شماره 

صفحات  -

تاریخ انتشار 2011