A reduced-FOV method for CINE MRI

نویسنده

  • B. MADORE
چکیده

Introduction: Several MRI applications involve imaging a dynamic object to resolve its temporal behavior. In such applications, it is often difficult to achieve the desired temporal resolution while maintaining the required spatial resolution and fieldof-view (FOV). Methods have been developed to increase the temporal resolution in the special case where only a fraction of the FOV undergoes dynamic changes [l-4]. Although cardiac imaging is an important example of an imaging application where motion is concentrated into only a part of the FOV, the reduced-FOV (rFOV) methods mentioned above are not compatible with one of the most common cardiac sequences, so-called ‘retrospective’ CINE imaging. The present work is a rFOV method designed to be compatible with CINE imaging, providing a decrease by a factor n in scan time (or an increase by a factor n in temporal resolution) if only l/nth of the FOV is dynamic, the rest being considered static.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of aortic distensibility in wild type and ApoE-knock-out mice at 9.4 T

Material and Methods C57/BL6 and ApoE-/mice (n=6 per group) were evaluated using a horizontal bore 9.4 T MRI animal scanner (Bruker, Karlsruhe, Germany) with a dedicated 2x2 phased-array surface coil. All MRI experiments were performed during general anesthesia using a mixture of isoflurane (2%) and oxygene (98%) applied by a mask covering nose and mouth of the animals. For cine imaging of the ...

متن کامل

Cardiac tagging with breath-hold cine MRI.

A method is presented for measuring myocardial deformation in a breath-hold with tagged cine MRI. Tagged cine images of human hearts are obtained in arbitrary oblique planes on a standard imager with as few as four heartbeats. The scan time has been reduced 16- to 64-fold from previous techniques.

متن کامل

A comparison of single-channel and multi-channel RF transmit coil for SSFP cine imaging at 3 Tesla

Introduction On high field MRI scanners uniform radio frequency (RF) excitation over the entire field-of-view (FOV) is often challenging with single-channel RF transmit coils. This may cause a reduction of image quality (e.g. shadowing artifacts). This problem is most pronounced in sequences that heavily rely on a homogenous magnetic field, such as steady state free precession (SSFP) sequences....

متن کامل

Improving cardiac cine MRI on 3T using 2D k-t accelerated auto-calibrating parallel imaging

Background Recently, 3D cine has gained attention due to its capability for single breath-hold volumetric measurement [1]. Nonetheless, conventional 2D cine maintains two intrinsic advantages, namely, its superior blood-myocardium contrast owing to blood in-flow effects and reduced SSFP banding artifacts with more localized slice-by-slice shimming. These advantages are more prominent at high fi...

متن کامل

مقایسه یافته های سونوگرافیک و MRI در ناهنجاری های جنینی

Background and purpose: Ultra sonography is the method of choice in pre-natal diagnosis of fetal anomalies however, sonography has limitations in oligohydramnios, maternal obesity and complex fetal anomalies. MRI, is a method with high contrast resolution, large FOV for fetus, placenta and uterine, along with multiplanar images. The aim of our study is to compare the sonographic and MRI findi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999