Make the Most of Time Temporal Extension of the iTV Algorithm for 4D Cardiac C-Arm CT

نویسندگان

  • Viktor Haase
  • Oliver Taubmann
  • Yixing Huang
  • Gregor Krings
  • Günter Lauritsch
  • Andreas K. Maier
  • Alfred Mertins
چکیده

Gated 4D cardiac imaging with C-arm CT scanners suffers from insufficient image quality due to strong angular undersampling. To deal with this problem, we suggest an iterative reconstruction method with spatial and temporal total variation regularization based on an established framework which controls the relative contributions of raw data error minimization and regularization. This new method is tested on a simulated heart phantom and on two clinical data sets. We show that the additional use of temporal regularization is advantageous compared to spatial regularization exclusively, with the relative root mean square error lowered from 11.75% to 8.24% in the phantom study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-resolved cardiac cone beam CT using an interventional C-arm system

It is both desirable and challenging to make interventional C-arm systems fit for cardiac cone beam CT. A number of methods towards this goal have been proposed, some of which even attempt to generate 4D images of the beating heart. A promising candidate of this type, proposed in [10, 12], is based on the (provable) assumption that the 3D image of the patient’s thorax at an arbitrary heart phas...

متن کامل

Cardiac C-arm computed tomography using a 3D + time ROI reconstruction method with spatial and temporal regularization.

PURPOSE Reconstruction of the beating heart in 3D + time in the catheter laboratory using only the available C-arm system would improve diagnosis, guidance, device sizing, and outcome control for intracardiac interventions, e.g., electrophysiology, valvular disease treatment, structural or congenital heart disease. To obtain such a reconstruction, the patient's electrocardiogram (ECG) must be r...

متن کامل

4D PET: Beyond conventional dynamic PET imaging

  In this paper, we review novel techniques in the emerging field of spatiotemporal 4D PET imaging. We will discuss existing limitations in conventional dynamic PET imaging which involves independent reconstruction of dynamic PET datasets. Various approaches that seek to attempt some or all of these limitations are reviewed in this work, including techniques that util...

متن کامل

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

Using four‐dimensional computed tomography images to optimize the internal target volume when using volume‐modulated arc therapy to treat moving targets

In this work we used 4D dose calculations, which include the effects of shape deformations, to investigate an alternative approach to creating the ITV. We hypothesized that instead of needing images from all the breathing phases in the 4D CT dataset to create the outer envelope used for treatment planning, it is possible to exclude images from the phases closest to the inhale phase. We used 4D ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016