CBCT-based volume of simulated root resorption - influence of FOV and voxel size.

نویسندگان

  • P F Da Silveira
  • M P Fontana
  • H W Oliveira
  • M B Vizzotto
  • F Montagner
  • H L Silveira
  • H E Silveira
چکیده

AIM To examine the influence of the field of view (FOV) and voxel size on the measurement of the volume of simulated internal root resorption (IRR) lesions through cone-beam computed tomography (CBCT). METHODOLOGY Eleven single-rooted teeth with IRR simulated by acid demineralization were studied. CBCT images were acquired using large FOV (voxel sizes of 0.200, 0.250 and 0.300 mm) and limited FOV (voxel sizes of 0.076, 0.100 and 0.200 mm). The IRR volumes were calculated using the Dolphin(®) software. Volumetric measurements were validated using IRR silicone putty casts. The analysis of variance (anova) for randomized block design complemented with the Tukey's test was employed. RESULTS IRR volumes obtained using voxel sizes of 0.200 and 0.250 mm were similar (P > 0.05). However, both these values were significantly different from that obtained using the 0.300-mm voxel (P < 0.05). There was no significant difference between IRR volumes measured through voxel sizes of 0.076 and 0.100 mm (P > 0.05), but both differed significantly from that obtained through the 0.200-mm voxel (P < 0.05). There was no significant difference between the volumetric measurements of the 0.200-mm voxel images of the restricted and large FOV protocols. The mean volumes of the silicone casts were smaller than those calculated using a 0.200-mm voxel, but were similar to those obtained using voxel sizes of 0.076 and 0.300 mm. CONCLUSIONS Despite the FOV protocol, voxel size can influence measurement of simulated IRR volumes. The importance of standardization of CBCT image acquisition protocols is emphasized, especially during follow-up of an IRR lesion, to prevent misinterpretation of its extent, which can create a bias in clinical decisions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of voxel size in the diagnostic ability of cone beam tomography to evaluate simulated external root resorption.

This study assessed in vitro the diagnostic ability of cone beam computed tomography (CBCT) scans with different voxel resolutions in the detection of simulated external root resorption (ERR). For that purpose, 59 teeth were viewed through iCAT tomography (Imaging Sciences International, Inc, Hatfield, PA) following three protocols in which the variation was the voxel resolution (0.4, 0.3, and ...

متن کامل

Effect of Voxel Size on Detection of External Root Resorption Defects Using Cone Beam Computed Tomography

BACKGROUND Selecting a voxel size that yields minimal radiation dose with no significant compromise of the diagnostic accuracy of cone beam computed tomography (CBCT) is particularly important. OBJECTIVES This study aimed to assess the effect of voxel size on detection accuracy of simulated external root resorption defects using NewTom CBCT system. MATERIALS AND METHODS In this diagnostic s...

متن کامل

Comparative assessment of subjective image quality of cross-sectional cone-beam computed tomography scans.

Since the introduction of cone-beam computed tomography (CBCT), several novel systems with different technical specifications and settings have become commercially available. Therefore, it is essential to evaluate CBCT systems for differences in the subjective quality of images obtained for various dental procedures. We evaluated the subjective image quality of cross-sectional scans obtained fr...

متن کامل

Diagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption.

AIM To compare in an ex vivo model the ability of digital intraoral radiography and cone beam computed tomography (CBCT) to detect simulated external inflammatory root resorption lesions, and to investigate the effect of altering the degree of rotation of the CBCT scanners X-ray source and imaging detector on the ability to detect the same lesions. METHODOLOGY Small and large simulated extern...

متن کامل

Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study

PURPOSE Field of view and voxel resolution of cone beam computed tomography (CBCT) might affect the diagnostic capability. This study was performed to compare between the standard and HiRes zoom modes in the diagnosis of external root resorption (ERR) using CBCT. MATERIALS AND METHODS Sixty three small cavities (0.25 mm depth and 0.5 mm diameter) were simulated on the buccal, lingual, and pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 48 10  شماره 

صفحات  -

تاریخ انتشار 2015