Intraocular lens power calculation after myopic and hyperopic laser vision correction using optical coherence tomography.

نویسندگان

  • Maolong Tang
  • Li Wang
  • Douglas D Koch
  • Yan Li
  • David Huang
چکیده

PURPOSE To use optical coherence tomography (OCT) to measure corneal power and calculate intraocular lens (IOL) power in cataract surgeries after myopic and hyperopic laser vision correction (LVC). METHODS Patients with previous LVC were enrolled in this prospective study at two centers (Doheny Eye Institute, Los Angeles, CA, USA and Cullen Eye Institute, Houston, TX, USA). Corneal power was measured with a Fourier-domain OCT system. The intravisit repeatability of OCT corneal power measurement was evaluated by the pooled standard deviation of repeat scans. Axial length, anterior chamber depth, and automated keratometry were measured with the IOLMaster. An OCT-based IOL formula was developed. The mean absolute error (MAE) of refractive prediction for OCT-based IOL formula was calculated. The results were compared with the MAE for Haigis-L formula. RESULTS A total of 31 eyes of 24 subjects who had uncomplicated cataract surgery with monofocal IOL implantation were enrolled in the two sites. Twenty-two eyes of 16 subjects had previous myopic LVC that ranged from -12.46 D to -0.88 D. Nine eyes of 8 subjects had previous hyperopic LVC that ranged from 0.66 D to 5.52 D. The intravisit repeatability of OCT corneal power measurement was 0.24 D. For the myopic LVC group, the OCT formula had a MAE of 0.57 D compared to an MAE of 0.73 D for the Haigis-L formula (p = 0.19). For the hyperopic LVC group, the MAE for OCT and Haigis-L formula was 0.26 D and 0.54 D, respectively (p > 0.05). CONCLUSIONS Corneal power can be precisely measured with OCT. The predictive accuracy of OCT-based IOL power calculation is equal to current standards for post-LVC eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical coherence tomography-based corneal power measurement and intraocular lens power calculation following laser vision correction (an American Ophthalmological Society thesis).

PURPOSE To use optical coherence tomography (OCT) to measure corneal power and improve the selection of intraocular lens (IOL) power in cataract surgeries after laser vision correction. METHODS Patients with previous myopic laser vision corrections were enrolled in this prospective study from two eye centers. Corneal thickness and power were measured by Fourier-domain OCT. Axial length, anter...

متن کامل

Estimation of Intraocular Lens Power Calculation after Myopic Corneal Refractive Surgery: Using Corneal Height in Anterior Segment Optical Coherence Tomography

PURPOSE To investigate the feasibility of estimating effective lens position (ELP) and calculating intraocular lens power using corneal height (CH), as measured using anterior segment optical coherence tomography (AS-OCT), in patients who have undergone corneal refractive surgery. METHODS This study included 23 patients (30 eyes) who have undergone myopic corneal refractive surgery and subseq...

متن کامل

Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

AIMS We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. METHODS Complete ophthalmologic examination and optical coherence tomogra...

متن کامل

Calculation of intraocular lens power using Orbscan II quantitative area topography after corneal refractive surgery.

PURPOSE To present the prospective application of the Orbscan II central 2-mm total-mean corneal power obtained by quantitative area topography in intraocular lens (IOL) calculation after refractive surgery. METHODS Calculated and achieved refraction and the difference between them were studied in 77 eyes of 61 patients with previous radial keratotomy (RK), RK and additional surgeries, myopic...

متن کامل

Wound healing profiles of hyperopic-small incision lenticule extraction (SMILE)

Refractive surgical treatment of hyperopia still remains a challenge for refractive surgeons. A new nomogram of small incision lenticule extraction (SMILE) procedure has recently been developed for the treatment of hyperopia. In the present study, we aimed to evaluate the wound healing and inflammatory responses of this new nomogram (hyperopic-SMILE), and compared them to those of hyperopic-las...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Saudi journal of ophthalmology : official journal of the Saudi Ophthalmological Society

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2012