Poster Abstract: Accurately Measuring Heart Rate Using Smart Watch

نویسندگان

  • Ho-Kyeong Ra
  • Jungmo Ahn
  • Hee Jung Yoon
  • JeongGil Ko
  • Sang Hyuk Son
چکیده

Smart watches are increasingly being used in various applications to monitor heart rate for exercise and health care purposes. It is crucial that the readings from these devices are accurate so that users can take proper actions according to the intensity of the heart rate. Taking actions from inaccurate readings can negatively impact the health of the user. In this work, we run a preliminary study that verifies the accuracy of wearable platforms by comparing the measurements with a clinically-grade device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recognition of Anaerobic based on Machine Learning using Smart Watch Sensor Data

In recent years, there has been an upsurge in research on smart watch technology. Existing research and commercial applications for machines that recognize user behaviors have involved measuring aerobic exercise using physical displacement metrics rather than anaerobic exercise, which involves recognizing and measuring user behaviors using signal processing techniques or other instruments. In t...

متن کامل

Validity and Reliability of the Apple Watch for Measuring Heart Rate During Exercise

The measurement of heart rate (HR) during acute exercise is one of the most common and pragmatic methods for estimating exercise intensity and prescribing exercise training thresholds [2, 17], although some studies suggest that the linear relationship between HR and oxygen consumption is sometimes altered [5]. Similarly, heart rate recovery following acute maximal or sub-maximal exercise is a c...

متن کامل

Lightweight wrist photoplethysmography for heavy exercise: motion robust heart rate monitoring algorithm

The challenge of heart rate monitoring based on wrist photoplethysmography (PPG) during heavy exercise is addressed. PPG is susceptible to motion artefacts, which have to be mitigated for accurate heart rate estimation. Motion artefacts are particularly apparent for wrist devices, for example, a smart watch, because of the high mobility of the arms. Proposed is a low complexity highly accurate ...

متن کامل

How to measure vessel flow with CMR phase contrast imaging

Background Accurately measuring blood flow with CMR is paramount in patients with valvular disease. These flow measurements are important components of a CMR report and provide the referring clinicians with valuable information in which to base further clinical management. This poster presents a guide on how to measure blood flow accurately based on our experience at the Bristol Heart Institute.

متن کامل

Implementation of Denoising Algorithms for Heart-Rate Estimation From Ambulatory Optical PPG

Wearable technology forms a fashion in today’s Emerging Embedded technology. Measuring clinical Parameters like Heart rate, Oxygen Saturation level using Smart Watches, Smart glasses from Photo – Plethysmogram (PPG) has become a new research topic in industry as well as academia in the area of Signal Processing and Embedded Environment. Extracting reasonable PPG signals to derive accurate Clini...