Comments on MR heating tests of critical implants.
نویسنده
چکیده
MAGNETIC RESONANCE IMAGING (MRI)-related heating for certain implants may be excessive, causing substantial patient injury. The determination of implant heating is particularly challenging because of the numerous variables that must be considered in order to properly identify both MRIand implant-related conditions that can impact the findings (1,2). Therefore, I applaud the recent commentary by Kainz (3), a member of the Food and Drug Administration (FDA), for presenting several of the confounding factors that complicate tests used to characterize implant heating. Kainz’s (3) guest editorial refers to possible issues associated with the in vitro assessment of MRI-related heating, with an emphasis on “MR critical implants.” MR critical implants were defined as: “active implantable medical devices (AIMDs); semiactive implants, i.e., implants powered from outside the body; and elongated metallic structures that are in the range of the critical length (defined later in the guest editorial) (3). Notably, there was no mention of devices that have ”resonant conducting loops,“ which may likewise generate excessive heating in association with MRI (4). Examples include cervical fixation devices and external fixation systems. As a member of the MRI community involved in the evaluation of implants since 1988 (5,6), I welcome the opportunity to respond to the content of this guest editorial insofar as our group and other investigators have extensive experience testing many of the so-called MR critical implants (7–23). In addition, we have been involved in the development of the methodology utilized to evaluate these devices (24). Importantly, findings from many studies have resulted in labeling approved by the U.S. Food and Drug Administration (FDA) to permit MRI procedures to be performed in patients with active, semiactive, and elongated devices, including cochlear implants, bone fusion stimulators, Foley catheters with temperature sensors, implantable infusion pumps, a deep brain stimulation system, spinal cord stimulators, a vagus nerve stimulator, a microstimulator (Bion), relatively long, orthopedic implants, and many others (7–23). As a result of this work, patients with “MR critical implants” throughout the world undergo MRI procedures safely, as MR healthcare workers follow FDA-approved guidelines (or guidelines approved by other agencies), which usually state specific instructions for a given device with respect to MRI parameters and other instructions. These instructions often indicate a particular whole-body averaged specific absorption rate (WB-SAR) that should not be exceeded during the MRI examination. For the aforementioned devices, the evaluation of MRI safety included an assessment of heating caused by MRI procedures. Interestingly, as the guest editorial indicates, “Most MR heating tests refer to [American Society for Testing and Materials International] ASTM Standard 2182-02a which is for passive implants only” (3). One of the reasons for this is that, currently, there is no standard for testing MR critical implants and, therefore, the ASTM standard used for passive implants has been modified to test active, semiactive, and elongated implants. In spite of this issue, the fact remains that the FDA approved MRI-related labeling for implants that utilized findings from heating tests suggested to be problematic. Notably, to date, there is no evidence that patient injuries have occurred in relation to the use of labeling approved by the FDA for these devices relative to the heating information. By comparison, there have been serious patient injuries related to not following specific instructions intended to prevent excessive implant heating (25–27).
منابع مشابه
Prosthetic heart valves and annuloplasty rings: assessment of magnetic field interactions, heating, and artifacts at 1.5 Tesla.
The purpose of this study was to determine the magnetic resonance (MR) safety aspects and artifacts for three different heart valve prostheses and two different annuloplasty rings that have not been evaluated previously in association with the 1.5-T MR environment. Ex vivo testing was performed using previously described techniques for the evaluation of magnetic field interactions (deflection a...
متن کاملAssessment of MRI issues at 7 T for 28 implants and other objects.
OBJECTIVE Metallic implants are currently a contraindication for volunteer subjects and patients referred for 7-T examinations because of concerns related to magnetic field interactions and MRI-related heating. Artifacts may also be problematic. Therefore, the purpose of this investigation was to evaluate these MRI issues for 28 implants and other objects in association with a 7-T MR system. ...
متن کاملMR labeling information for implants and devices: explanation of terminology.
Frank G. Shellock, PhD Terry O. Woods, PhD John V. Crues III, MD The magnetic resonance (MR) environment may pose risks or problems to patients with certain implants and other medical devices primarily due to factors that include electromagnetic field interactions, MR imaging–related heating, and the creation of artifacts (1–5). In addition, for electrically activated implants and other medical...
متن کاملMR safety assessment of potential RF heating from cranial fixation plates at 7 T.
PURPOSE The increasing number of clinically oriented MRI studies at 7 T motivates the safety assessment of implants, since many 7 T research sites conservatively exclude all subjects with metallic implants, regardless of type or location. The purpose of this study was to investigate potential RF-induced heating during a 7 T MRI scan using a self-built transmit/receive RF coil in patients with i...
متن کاملSafety of metallic implants in magnetic resonance imaging.
Magnetic resonance (MR) imaging has become a commonly accepted medical procedure. Manufacturers of medical implant devices are submitting claims that their devices are safe and effective in a MR environment. This paper concentrates on the issue of heating of patients due to the interaction of metallic implants with the strong radiofrequency (RF) magnetic field produced by the MR scanner. The co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 26 5 شماره
صفحات -
تاریخ انتشار 2007