Temporal Resolution Improvement in Single Source and Dual Source CT

نویسندگان

  • Clemens Maaß
  • Marc Kachelrieß
چکیده

Purpose: Recently a new method called TRIPICCS (Temporal Resolution Improved Prior Image Constrained Compressed Sensing) was proposed to improve the temporal resolution of a single source (SS) cardiac CT scan [1] (figures 1+2). This method aims at doubling the temporal resolution and at maintaining homogeneous temporal resolution independently of the location and the motion direction of a vessel. The aims of our study are two-fold. First we independently evaluate TRI-PICCS regarding the reported improvements and then we extend the algorithm to dual source CT and evaluate the results there as well. TRI-PICCS is compared with a standard short scan reconstruction regarding two properties: The temporal resolution (TR) and the dependency of the TR on the motion direction of a vessel (=reproducibility). Both properties are evaluated as a function of the position within the field of measurement (FOM).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ایمنی و عملکرد سی تی اسکن dual-source در مقایسه با سی تی اسکن single-source  و آنژیوگرافی مرسوم در تشخیص بیماری های عروق کرونر قلب(مطالعه مروری نظام مند)

Background: The aim of this study is to explore the safety and diagnostic performance of dual-source CT scan in comparison with single source CT scan and conventional angiography in patients with coronary heart diseases.Materials and methods: A systematic review was performed using CRD standard methods. The Cochrane Library, MEDLINE, EMBASE، Google Scholar and TRIP were searched up to April 200...

متن کامل

Four-Dimensional Real-Time Cine Images of Wrist Joint Kinematics Using Dual Source CT with Minimal Time Increment Scanning

PURPOSE To validate the feasibility of real time kinematography with four-dimensional (4D) dynamic functional wrist joint imaging using dual source CT. MATERIALS AND METHODS Two healthy volunteers performed radioulnar deviation and pronation- supination wrist motions for 10 s and 4 s per cycle in a dual source CT scanner. Scan and reconstruction protocols were set to optimize temporal resolut...

متن کامل

Investigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]

By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...

متن کامل

Dual-time-point FDG-PET/CT Imaging of Temporal Bone Chondroblastoma: A Report of Two Cases

Temporal bone chondroblastoma is an extremely rare benign bone tumor. We encountered two cases showing similar imaging findings on computed tomography (CT), magnetic resonance imaging (MRI), and dual-time-point 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT. In both cases, CT images revealed temporal bone defects and sclerotic changes around the tumor. Most parts of the ...

متن کامل

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010