Simultaneous Determination of Metformin, Nateglinide and Gliclazide in Pharmaceutical Preparations Using Micellar Liquid Chromatography

نویسنده

  • Dalia Rashad El-Wasseef
چکیده

A micellar chromatographic method has been developed and validated for simultaneous separation and determination of metformin(MF), nateglinide (NT) and gliclazide (GL). The separation was carried out using a Nucleosil C18 column, 150 mm × 4.6 mm i.d., 5 μm particle size, using micellar mobile phase consisting of sodium dodecyl sulphate (SDS), n-propanol with UV detection. The optimum conditions for the simultaneous separation of the three drugs were 0.12 M SDS, 10% (v/v) n-popanol, 0.3% triethylamine adjusted to pH5.6 with a flow rate of 1 ml.min(-1) and detection at 254 nm. The limit of detection (LOD) of MF, NT, GL were 0.047, 0.00115, 0.036 μg.mL(-1) respectively. The method showed good linearity in the ranges of 0.4-16 μg.mL(-1), (r(2)=0.999), 0.8-16 μg.ml(-1) (r(2)=0.999) and 1-40 μg.ml(-1) (r(2)=0.999) for MF, NT, GL respectively. The suggested method was successfully applied for the analysis of the three antidiabetic drugs in pharmaceutical preparations with average recoveries of 99.66%, 100.08% and 100.31% for MT, NT and GL respectively. The results obtained were in good agreement with those obtained from comparison methods. The method was validated regarding accuracy and precision.

منابع مشابه

Simultaneous Quantification of Antidiabetic Agents in Human Plasma by a UPLC–QToF-MS Method

An ultra-performance liquid chromatography quadrupole time-of-flight mass spectrometry method for the simultaneous quantification of chlorpropamide, glibenclamide, gliclazide, glimepiride, metformin, nateglinide, pioglitazone, rosiglitazone, and vildagliptin in human plasma was developed and validated, using isoniazid and sulfaquinoxaline as internal standards. Following plasma protein precipit...

متن کامل

Development and validation of analytical method for the estimation of nateglinide in rabbit plasma

Nateglinide has been widely used in the treatment of type-2 diabetics as an insulin secretogoga. A reliable, rapid, simple and sensitive reversed-phase high performance liquid chromatography (RP-HPLC) method was developed and validated for determination of nateglinide in rabbit plasma. The method was developed on Hypersil BDSC-18 column (250 mm×4.6 mm, 5 mm) using a mobile phase of 10 mM phosph...

متن کامل

Development And Validation Of A Hplc Method For The Determination Of Metformin Hydrochloride, Gliclazide And Piogliglitazone Hydrochloride In Multicomponent Formulation

A simple, rapid, and precise reversed-phase high-performance liquid chromatographic method for simultaneous analysis of metformin hydrochloride, gliclazide, and pioglitazone hydrochloride in a tablet dosage form has been developed and validated. Chromatography was performed on a 25 cm × 4.6 mm i.d., 5-μm particle, C18 column with 85:15 (v/v) methanol: 20 mM potassium dihydrogen phosphate buffer...

متن کامل

Comparison of nateglinide and gliclazide in combination with metformin, for treatment of patients with Type 2 diabetes mellitus inadequately controlled on maximum doses of metformin alone

AIM To compare the effects of nateglinide plus metformin with gliclazide plus metformin on glycaemic control in patients with Type 2 diabetes. METHODS Double-blind, double-dummy, parallel group, randomized, multicentre study over 24 weeks. Patients with inadequate glucose control on maximal doses of metformin were randomized to additionally receive nateglinide (n = 133) or gliclazide (n = 129...

متن کامل

Separation and Quantification of Eight Antidiabetic Drugs on A High-Performance Liquid Chromatography: Its Application to Human Plasma Assay

An analytical method based on isocratic reverse phase high-performance liquid chromatography was developed and validated for the separation and quantification of eight antidiabetic drugs: rosiglitazone, pioglitazone, glipizide, gliclazide, repaglinide, nateglinide, glibenclamide, and glimepiride for their application in human plasma assay. Metformin is used as internal standard. Analysis was do...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2012