Plasma endothelin-1 levels in patients with systemic sclerosis: influence of pulmonary or systemic arterial hypertension.

نویسندگان

  • S Morelli
  • C Ferri
  • L Di Francesco
  • R Baldoncini
  • M Carlesimo
  • U Bottoni
  • G Properzi
  • A Santucci
چکیده

OBJECTIVES To investigate the behaviour of circulating endothelin-1 (ET-1) in patients affected by systemic sclerosis and to elucidate the relationship between systemic and pulmonary plasma peptide and arterial pressure levels. METHODS Plasma ET-1 concentrations were determined in 48 patients affected by systemic sclerosis (41 women, seven men; mean age 47.2 (SD 5.5) years) with or without systemic or pulmonary hypertension (or both). A group of 18 normal volunteers served as controls (15 women, three men; mean age 45.0 (10.1) years). RESULTS Plasma ET-1 levels were significantly greater in patients affected by systemic sclerosis (1.65 (0.29) pg/ml) than in controls (0.63 (0.19) pg/ml) (p < 0.0001). Pulmonary artery systolic hypertension alone was present in 14 patients with systemic sclerosis (50.5 (8.49) mm Hg, range 37-67 mm Hg), and systemic hypertension alone (160.7 (5.9)/100.6 (3.2) mm Hg) was present in 11 patients. Both conditions were present in 12 patients, while 11 patients had systemic hypertension. There were no significant differences in plasma ET-1 levels between patients with pulmonary hypertension alone (1.62 (0.21) pg/ml) and those with systemic hypertension alone (1.65 (0.43) pg/ml). In particular, patients with normal pulmonary artery and systemic pressures (n = 11) had plasma ET-1 concentrations identical to those found in patients (n = 12) with both pulmonary and systemic hypertension (1.70 (0.15) v 1.64 (0.35) pg/ml, respectively). No correlations were observed between plasma ET-1 and either pulmonary or systemic pressures. CONCLUSION Systemic sclerosis is characterised by increased plasma ET-1 levels, but neither pulmonary nor systemic hypertension are accompanied by further increase in plasma peptide levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful treatment of systemic sclerosis digital ulcers and pulmonary arterial hypertension with endothelin receptor antagonist bosentan.

SIR, We read with interest the recent reports describing the promising results of studies exploring the role of the dual endothelin receptor antagonist bosentan in pulmonary arterial hypertension (PAH) w1, 2x. We report the case of a patient with systemic sclerosis associated with PAH and ischaemic digital ulcerations who responded successfully to bosentan. A 50-yr-old male dentist presented in...

متن کامل

THE EFFECTS OF CAPTOPRIL ON PULMONARY AND SYS TEMIC ARTERIAL PRESSURES IN HIGHALTITUDE PULMONARY HYPERTENSION

The purpose of this investigation was to assess the effect of captopril on both systemic (P.a) and pulmonary arterial pressures (PPA) in patients with high-altitude pulmonary hypertension (HAPH). Seventeen patients (mean age 44±6.8 years) with HAPH and mild to moderate systemic arterial hypertension were included in the study. All patients underwent right heart catheterization with measurem...

متن کامل

Endothelin-1 has haemodynamic effects at pathophysiological concentrations in patients with left ventricular dysfunction.

OBJECTIVES Plasma levels of immunoreactive endothelin-1 (ET-1) are raised in chronic heart failure. Whether plasma ET-1 contributes to the haemodynamic derangement found in chronic heart failure is not known. We investigated the effects of exogenous ET-1 on the pulmonary and systemic vasculature in patients with left ventricular systolic dysfunction (LVD), with or without overt heart failure. ...

متن کامل

Combined use of ursodeoxycholic acid and bosentan prevents liver toxicity caused by endothelin receptor antagonist bosentan monotherapy: two case reports

INTRODUCTION Pulmonary arterial hypertension is a fatal disease characterized by progressive remodeling of the pulmonary arteries and an increase in pulmonary vascular resistance. Up to 50% of patients with systemic sclerosis have pulmonary arterial hypertension, which significantly affects the prognosis. The endothelin receptor antagonist bosentan is used for the treatment of pulmonary arteria...

متن کامل

Infliximab treatment efficacy in lymphoedema associated with ankylosing spondylitis.

2003;47(Suppl.):1137. 6. Humbert M, Cabane J. Successful treatment of systemic sclerosis digital ulcers and pulmonary arterial hypertension with endothelin receptor antagonist bosentan. Rheumatology 2003;42:191–3. 7. Thompson AE, Shea B, Welch V, Fenlon D, Pope JE. Calciumchannel blockers for Raynaud phenomenon in systemic sclerosis. Arthritis Rheum 2001;44:1841–7. 8. Rodnan GP, Myerowitz RL, J...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the rheumatic diseases

دوره 54 9  شماره 

صفحات  -

تاریخ انتشار 1995