Bubble mixing device for blood sampling by automatic analysis.

نویسندگان

  • H N NAUMANN
  • A M OLSEN
  • J M YOUNG
چکیده

JHE RESULTS of blood glucose determinations and, to a lesser extent, of blood urea nitrogen determinations by an automatic analysis device* have been observed to be significantly lower than those of the commonly used routine methods (1, 2). A cause of these discrepancies was the gradually increasing sedimentation of cells in blood samples during an hour of processing, with resultant pick-up of blood suspensions progressively richer in cells and with lower glucose and urea nitrogen concentrations. This problem was solved by the use of a bubble mixing device that produces uniform blood suspensions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Method for the estimation of phenothiazine derivatives in urine and blood.

A New Approach to Acid-Base Metabolism Poul Astrup 1 Plasma and Red Cell Cholesterol Gordon Fels, Eugene Kanobrocki, and Ervin Kaplan 16 The Polarographic Determination of Selenium in Urine Albert 0. Faulkner, Edward C. Knoblock, and William C. Purdy 22 Factors Affecting the Estimation of Pregnanediol in Human Urine G. S. Duboff , H. Saraiya, and S. .1. Behrman 30 Simplified Determination of th...

متن کامل

A New Statistical Parameter for Identifying the Main Transition Velocities in Bubble Columns*

The identification of the main flow regime boundaries in bubble columns is essential since the degrees of mixing and mass and heat transfer vary with the flow regime. In this work, a new statistical parameter was extracted from the time series of the cross-sectional averaged gas holdup. The measurements were performed in bubble columns by means of conductivity wire-mesh sensors at very high sam...

متن کامل

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...

متن کامل

A method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow

Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...

متن کامل

A method for detecting bubbles in two-phase gas-liquid flow

Detecting bubble in two-phase flow has been a basic issue in two-phase flow systems. A new method for measuring the frequency of bubble formation is presented in this paper. For this purpose, an electronic device was designed and constructed which works based on a change in intensity of laser beam. For this purpose, continues light beam is embedded just above the needle, which is received by a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 7  شماره 

صفحات  -

تاریخ انتشار 1961