Radiopacity evaluation of composite restorative resins and bonding agents using digital and film x-ray systems

نویسندگان

  • Bengi Oztas
  • Sebnem Kursun
  • Gul Dinc
  • Kıvanc Kamburoglu
چکیده

OBJECTIVE The purpose of this in vitro study was to explore the radiopacity of composite resins and bonding materials using film and phosphor plates. METHODS Nine composite dental resin specimens and human tooth slices were exposed together with an aluminium stepwedge using dental film and phosphor plates. Eight dentin bonding specimens were prepared and exposed in a similar manner. Their radiopacity on film was assessed using a transmission densitometer, and the radiopacity with phosphor plates was assessed digitally using the system's own software (Digora). Data were analysed using one-way analysis of variance (ANOVA) and post-hoc Tukey tests (P<.05). Film and phosphor plate radiopacity values were compared using simple regression analysis. RESULTS Excellent linear correlation was found between film and phosphor plates for both composite resins and bonding agents. The composite materials Spectrum Tph and Natural Look exhibited the highest radiopacity with film and with phosphor plates, respectively. All the dentin bonding agents tested exhibited lower radiopacity than dentin. CONCLUSION Synergy, Ice, Filtek Silorane, Filtek Z250, Clearfil Majesty Posterior, Herculite Classic, Spectrum Tph, and Natural Look composite materials exhibited greater radiopacity than dentin, and all the dentin bonding agents tested exhibited lower radiopacity than either enamel or dentin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of radiopacity of restorative composite resins with various target distances and exposure times and a modified aluminum step wedge

PURPOSE ANSI/ADA has established standards for adequate radiopacity. This study was aimed to assess the changes in radiopacity of composite resins according to various tube-target distances and exposure times. MATERIALS AND METHODS Five 1-mm thick samples of Filtek P60 and Clearfil composite resins were prepared and exposed with six tube-target distance/exposure time setups (i.e., 40 cm, 0.2 ...

متن کامل

Radiopacity evaluation of contemporary resin composites by digitization of images

OBJECTIVE The aim of this study was to evaluate the radiopacity of different composite resins and compare the values to those of human enamel and dentine. MATERIALS AND METHODS Five specimens of each material with thicknesses of 2 mm were prepared and radiographed alongside aluminum step wedge and human enamel and dentin. Three occlusal radiographs for each material were taken and digitized u...

متن کامل

Radiopacity assessment of composite resins through digital systems and InSight intraoral film Avaliação da radiopacidade de resinas compostas por meio de sistemas digitais e filme radiográfico InSight

RFO, Passo Fundo, v. 18, n. 2, p. 175-179, maio/ago. 2013 * DDS, PhD, professor, University of Passo Fundo, Passo Fundo, RS, Brazil. ** DDS, PhD, professor, University of Campinas, Campinas, SP, Brazil. *** DDS, PhD, chairman, University of Campinas, Campinas, SP, Brazil. **** DDS, MS, professor, University of Passo Fundo, Passo Fundo, RS, Brazil. ***** DDS, PhD, professor, University of Pelota...

متن کامل

Radiopacity of 28 Composite Resins for Teeth Restorations.

AIM Radiopacity is a fundamental requisite to check marginal adaptation of restorations. Our objective was to assess the radiopacity of 28 brands of light-cured composite resins and compare their radiopacity with that of enamel, dentin, and aluminum of equivalent thickness. MATERIALS AND METHODS Composite resin disks (0.2, 0.5, and 1 mm) were radiographed by the digital method, together with ...

متن کامل

Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions

PURPOSE This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. MATERIALS AND METHODS Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012