Multianalyte quantification of vitamin B6 and B2 species in the nanomolar range in human plasma by liquid chromatography-tandem mass spectrometry.

نویسندگان

  • Oivind Midttun
  • Steinar Hustad
  • Einar Solheim
  • Jørn Schneede
  • Per M Ueland
چکیده

BACKGROUND Homocysteine, a risk factor of cardiovascular disease, cognitive disorders, and pregnancy complications, exists at a point of metabolic convergence of several B vitamins, including vitamins B(6) and B(2) (riboflavin). Measurement of the various forms of these vitamins may be useful for the study of hyperhomocysteinemia as well as for the assessment of vitamin status. METHODS Plasma (60 microL) was deproteinized by mixing with an equal volume of 50 g/L trichloroacetic acid that contained d(2)-pyridoxal 5'-phosphate, d(3)-pyridoxal, and d(8)-riboflavin as internal standards. Pyridoxal (PL), pyridoxal 5'-phosphate (PLP), pyridoxine (PN), pyridoxine 5'-phosphate, pyridoxamine (PM), pyridoxamine 5'-phosphate, 4-pyridoxic acid (PA), riboflavin, flavin mononucleotide (FMN), and FAD were separated on a C(8) reversed-phase column, which was developed with an acetonitrile gradient in a buffer containing acetic acid and heptafluorobutyric acid. The analytes were detected by tandem mass spectrometry in the positive-ion mode. RESULTS The chromatographic run lasted 8 min. Within- and between-day CVs were 3%-20% and 6%-22%, respectively, and recoveries were 78%-163%. Limits of detection (signal-to-noise ratio = 5) were in the range 0.1-4.0 nmol/L, and the response was linear over several orders of magnitude. In samples from 94 healthy persons, we obtained median concentrations (nmol/L) of 35.4 for PLP, 16.9 for PL, 22.4 for PA, 10.3 for riboflavin, 7.5 for FMN, and 63.1 for FAD. PN and PM were also detected in some cardiovascular patients taking B(6) supplements. CONCLUSIONS This method based on liquid chromatography-tandem mass spectrometry measures all known plasma forms of vitamins B(6) and B(2), which span a wide range of polarity. The assay is characterized by simple sample processing with no derivatization, low sample volume requirement, and a short run time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

A quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 51 7  شماره 

صفحات  -

تاریخ انتشار 2005