Comparison of Hypersensitivity in Metal Ceramic Crowns cemented with Zinc Phosphate and Self-adhesive Resin: A Prospective Study.

نویسندگان

  • Thatapudi Shankar
  • Mirna Garhnayak
  • Lokanath Garhnayak
  • Angurbala Dhal
  • Aswini K Kar
چکیده

BACKGROUND Luting agents used to fix artificial prostheses, such as fixed partial denture (FPD) to tooth are basically viscous in nature and show chemical reaction for fixation. Postcementation hypersensitivity is a frequent complaint of patients. The present study was conducted to compare postcementation hypersensitivity with zinc phosphate and self-adhesive resin in complete coverage crown. MATERIALS AND METHODS This study included 30 patients in which 60 porcelein fused to metal crowns was placed. Two metal crowns were placed in each patient in nonantagonis-tic contralateral quadrants. First crown was cemented with zinc phosphate cement, while the other was cemented with self-adhesive resin. Hypersensitivity was evaluated by visual analog scale (VAS) score and by clinical test. For clinical evaluation of sensitivity, hot and cold water was applied to the cervical margin of restoration for 5 seconds and response was recorded. RESULTS This study consisted of 30 patients in which 60 crowns were given. There was no statistical difference in VAS score of mastication in zinc phosphate cement recorded at baseline, 1 week, 4 weeks, 6 months, 1 year, and 2 years (p > 0.05). Cold response also did not show a significant difference at six time points. Warm response showed slight decrease in subsequent time points but was nonsignificant (p > 0.05). Similarly, with self-adhesive resin cement, VAS score during mastication, hot and cold response was statistically nonsignificant (p > 0.05). CONCLUSION Postcementation hypersensitivity is a frequent complaint that patient may experience. However, we found no statistically significant difference in both cements tested. CLINICAL SIGNIFICANCE Postcementation hypersensitivity is an unpleasant sensation experienced by patients. This may affect the success of any prosthesis. Thus, selection of luting agent for cementation plays an important role to eliminate this symptom.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Hypersensitivity in Metal Ceramic Crowns cemented with Zinc Phosphate and Self-adhesive Resin

Background: Luting agents used to fix artificial prostheses, such as fixed partial denture (FPD) to tooth are basically viscous in nature and show chemical reaction for fixation. Postcementation hypersensitivity is a frequent complaint of patients. The present study was conducted to compare postcementation hypersensitivity with zinc phosphate and self-adhesive resin in complete coverage crown. ...

متن کامل

Longevity of metal-ceramic crowns cemented with self-adhesive resin cement: a prospective clinical study

Resin cements are often used for single crown cementation due to their physical properties. Self-adhesive resin cements gained widespread due to their simplified technique compared to regular resin cement. However, there is lacking clinical evidence about the long-term behavior of this material. The aim of this prospective clinical trial was to assess the survival rates of metal-ceramic crowns ...

متن کامل

Influence of cementation and cement type on the fracture load testing methodology of anterior crowns made of different materials.

To evaluate the influence of cementation on fracture load of anterior crowns made of CAD/CAM-resin-blocks (ART), leucite-reinforced glass-ceramics (LRG), lithium disilicate ceramics (LIT), veneered zirconia (ZRO) and veneered alloy (DEG). Each crown group (n=15/subgroup) was cemented on the metal abutment as follows: i. using glass ionomer, ii. using self-adhesive resin cement, and iii. not cem...

متن کامل

Marginal Fit Metal-Ceramic and In-Ceram Single Crown Cement retained in Implant-supported Abutments.

INTRODUCTION This study evaluated the cervical fit of cemented metal-ceramic and In-Ceram implant-supported crowns, before and after the cementing procedure. MATERIALS AND METHODS Twenty crowns cemented on implant abutments are divided into two groups (n = 10): Group 1 -cemented metal-ceramic crowns and group 2 - cemented In-Ceram crowns. The marginal adaptations before and after cementation ...

متن کامل

A split-mouth randomized clinical trial of single crowns retained with resin-modified glass-ionomer and zinc phosphate luting cements.

PURPOSE This study compared the influence of two luting cements on the clinical performance of single crowns. MATERIALS AND METHODS Twenty patients received 39 pairs of metal-ceramic and Procera crowns cemented with zinc phosphate and resin-modified glass-ionomer luting cement (Vitremer) in a split-mouth randomized pattern blinded to the recipient. The crowns were examined immediately after c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 18 10  شماره 

صفحات  -

تاریخ انتشار 2017