Cyclohexanone contamination from extracorporeal circuits impairs cardiovascular function.
نویسندگان
چکیده
Extracorporeal circulation provides critical life support in the face of cardiopulmonary or renal failure, but it also introduces a host of unique morbidities characterized by edema formation, cardiac insufficiency, autonomic dysfunction, and altered vasomotor function. We tested the hypothesis that cyclohexanone (CHX), a solvent used in production of extracorporeal circuits and intravenous (IV) bags, leaches into the contained fluids and can replicate these clinical morbidities. Crystalloid fluid samples from circuits and IV bags were analyzed by gas chromatography-mass spectrometry to provide a range of clinical CHX exposure levels, revealing CHX contamination of sampled fluids (9.63-3,694 microg/l). In vivo rat studies were conducted (n = 49) to investigate the effects of a bolus IV infusion of CHX vs. saline alone on cardiovascular function, baroreflex responsiveness, and edema formation. Cardiovascular function was evaluated by cardiac output, heart rate, stroke volume, vascular resistance, arterial pressure, and ventricular contractility. Baroreflex function was assessed by mean femoral arterial pressure responses to bilateral carotid occlusion. Edema formation was assessed by the ratio of wet to dry organ weights for lungs, liver, kidneys, and skin. CHX infusion led to systemic hypotension; pulmonary hypertension; depressed contractility, heart rate, stroke volume, and cardiac output; and elevated vascular resistance (P < 0.05). Mean arterial pressure responsiveness to carotid occlusion was dampened after CHX infusion (from +17.25 +/- 1.8 to +5.61 +/- 3.2 mmHg; P < 0.05). CHX infusion led to significantly higher wet-to-dry weight ratios vs. saline only (3.8 +/- 0.06 vs. 3.5 +/- 0.05; P < 0.05). CHX can reproduce clinical cardiovascular, neurological, and edema morbidities associated with extracorporeal circulatory treatment.
منابع مشابه
Sterility of Previously Assembled Cardiopulmonary Bypass Circuits
The sterility of previously assembled cardiopulmonary bypass circuits was investigated for 17 extracorporeal circuits. The closed circuits were assembled using aseptic technique and remained in the operating room until the time of use. The mean time from point of setup to point of priming for the 17 randomly chosen circuits was 21.47 hours, with a range of 13.50 to 60.50 hours. Circuits were pr...
متن کاملBlood and breath profiles of volatile organic compounds in patients with end-stage renal disease
BACKGROUND Monitoring of volatile organic compounds (VOCs) in exhaled breath shows great potential as a non-invasive method for assessing hemodialysis efficiency. In this work we aim at identifying and quantifying of a wide range of VOCs characterizing uremic breath and blood, with a particular focus on species responding to the dialysis treatment. METHODS Gas chromatography with mass spectro...
متن کاملInvestigations into the sterility of manually assembled extracorporeal circuits with vented reservoirs.
This study was designed to investigate the ability of an extracorporeal circuit (ECC) with a vented hard shell reservoir to remain sterile for a period of 72 h under dry conditions. The study was conducted in three phases. In Phase One: Two previously published methods for detecting contamination of the ECC were compared. A group of positive controls was collected by contaminating identical cir...
متن کاملMorphine Consumption During Lactation Impairs Short-Term Neuronal Plasticity in Rat Offspring CA1 Neurons
Background: Facing environmental factors during early postnatal life, directly or indirectly via mother-infant relationships, profoundly affects the structure and function of the mammals’ Central Nervous System (CNS). Objectives: This study aimed to evaluate the effect of morphine consumption during the lactation period on short-term synaptic plasticity of the hippocampal Cornu Ammonis 1 (C...
متن کاملIn vitro drug adsorption and plasma free hemoglobin levels associated with hollow fiber oxygenators in the extracorporeal life support (ECLS) circuit.
The purpose of this study was to identify the percentage of fentanyl or morphine sulfate lost from adhesion to either the polyvinylchloride (PVC) tubing or the surface of two different hollow fiber oxygenators used in current extracorporeal life support circuits and to identify any difference in the plasma free hemoglobin (PFH) levels generated when using these oxygenator and/or drug combinatio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 296 6 شماره
صفحات -
تاریخ انتشار 2009