Caveats of pressure control: lung non-protective ventilation.
نویسندگان
چکیده
Editor—Lung-protective ventilation (LPV), in which the tidal volume is restricted to 6 ml kg and the plateau pressure to ,30 cm H2O, is the accepted standard of care for patients with acute lung injury (ALI) and the acute respiratory distress syndrome (ARDS). A growing body of evidence supports the implementation of LPV in patients with other forms of acute respiratory failure and even in patients with healthy lungs undergoing general anaesthesia for elective surgery. The evidence behind LPV is largely based upon studies that have used volume-controlled modes of mechanical ventilation. Pressurecontrolled modes ofventilation offer the theoretical advantages of better patient–ventilator synchrony and improved patient comfort. However, in critically ill patients, airway resistance and lung compliance change on a minute-to-minute basis; therefore, the delivery of a fixed inspiratory pressure may result in gross underor over-ventilation. Although pressurecontrolled modes of ventilation have been the mainstay of ventilation bundles in British intensive care units (ICUs) for decades, conciliating this strategy with a lung-protective model may prove difficult. Our large medical/surgical ICU is located in a tertiary care centre. A Bi-level/pressure support-based, nurse-led ventilation strategy is the default for all patients, with patients generally weaned from Bi-level to pressure support as soon as able. We retrospectively analysed data extracted from the electronic patient records of 200 mechanically ventilated patients sequentially admitted to ICU for mechanical ventilation during a 6 month period (November 2013–April 2014). The tidal ventilation administered was determined by averaging the hourly tidal volume recorded over the first 24 h of admission. An ‘ideal’ tidal volume (6 ml kg) was calculated for each patient based on ideal body weight. The average age of the study population was 58, with an average duration of mechanical ventilation of 4.1 days and an ICU length of stay of 6.1 days: 43% of patients were admitted after abdominal or vascular surgery; 29% of patients were ventilated for neurological protection; 20% of patients had ALI/ARDS on admission; and 5% had communityacquired pneumonia. Analysis of the data revealed that average tidal volume received by the patients during their first 24 h of admission was 536 (40) ml, which represents an excess of 88.2 (30) ml over the ‘ideal’ lung-protective tidal volume (P,0.05). Moreover, in patients with ALI/ARDS, the tidal volume delivered was 544 ml (30), which represents an excess of 95 (25) ml (P,0.05) over ideal volumes. These figures demonstrate that, in our institution, the application of a pressure control-based ventilation strategy resulted in the delivery of ventilation significantly larger than the recommended LPV standard. This effect was observed in both mandatory (Bi-level) and spontaneous (pressure support) modes of ventilation. While the effect of restricting tidal volumes to 6 ml kg in spontaneously ventilating patients remains controversial, given the state of the evidence, it seems reasonable to adhere to LPV recommendations at least in the initial acute stage of respiratory failure, where the potential for ventilation-induced lung injury is highest. Achieving this with the use of pressurecontrol-based ventilation requires regular and meticulous titration of pressures, significantly increases the nursing workload, and, as demonstrated by our results, may be ultimately unfeasible in a busy tertiary referral centre. The recently developed dual-control modes of ventilation, which are pressure-based but have auto-regulation mechanisms that restrict delivered volumes, may represent a promising middle ground that warrants further assessment in the clinical setting.
منابع مشابه
Protective ventilation reduces Pseudomonas aeruginosa growth in lung tissue in a porcine pneumonia model
BACKGROUND Mechanical ventilation with positive end expiratory pressure and low tidal volume, i.e. protective ventilation, is recommended in patients with acute respiratory distress syndrome. However, the effect of protective ventilation on bacterial growth during early pneumonia in non-injured lungs is not extensively studied. The main objectives were to compare two different ventilator settin...
متن کاملLung protection during non-invasive synchronized assist versus volume control in rabbits
INTRODUCTION Experimental work provides insight into potential lung protective strategies. The objective of this study was to evaluate markers of ventilator-induced lung injury after two different ventilation approaches: (1) a "conventional" lung-protective strategy (volume control (VC) with low tidal volume, positive end-expiratory pressure (PEEP) and paralysis), (2) a physiological approach w...
متن کامل[Ventilation strategies in the child with severe hypoxemic respiratory failure].
In this review, we assemble the fundamental concepts of the use of mechanical ventilation (MV) in children with acute respiratory failure (ARDS) and refractory hypoxemia. We also discusses topics of protective ventilation and recruitment potential, and specifically examine the options of ventilation and/or maneuvers designed to optimize the non-aerated lung tissue: alveolar recruitment maneuver...
متن کاملIntra-operative adherence to lung-protective ventilation: a prospective observational study
BACKGROUND Lung-protective ventilation in patients with acute respiratory distress syndrome improves mortality. Adopting this strategy in the perioperative period has been shown to reduce lung inflammation and postoperative pulmonary and non-pulmonary sepsis complications in patients undergoing major abdominal surgery. We conducted a prospective observational study into the intra-operative vent...
متن کاملOriginal Contributions Work of Breathing During Lung-Protective Ventilation in Patients With Acute Lung Injury and Acute Respiratory Distress Syndrome: A Comparison Between Volume and Pressure-Regulated Breathing Modes
BACKGROUND: Pressure-control ventilation (PCV) and pressure-regulated volume-control (PRVC) ventilation are used during lung-protective ventilation because the high, variable, peak inspiratory flow rate (V̇I) may reduce patient work of breathing (WOB) more than the fixed V̇I of volume-control ventilation (VCV). Patient-triggered breaths during PCV and PRVC may result in excessive tidal volume (VT...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 113 6 شماره
صفحات -
تاریخ انتشار 2014