Nuclear Radiation Degradation Study on HD Camera Based on CMOS Image Sensor at Different Dose Rates
نویسندگان
چکیده
In this work, we irradiated a high-definition (HD) industrial camera based on a commercial-off-the-shelf (COTS) CMOS image sensor (CIS) with Cobalt-60 gamma-rays. All components of the camera under test were fabricated without radiation hardening, except for the lens. The irradiation experiments of the HD camera under biased conditions were carried out at 1.0, 10.0, 20.0, 50.0 and 100.0 Gy/h. During the experiment, we found that the tested camera showed a remarkable degradation after irradiation and differed in the dose rates. With the increase of dose rate, the same target images become brighter. Under the same dose rate, the radiation effect in bright area is lower than that in dark area. Under different dose rates, the higher the dose rate is, the worse the radiation effect will be in both bright and dark areas. And the standard deviations of bright and dark areas become greater. Furthermore, through the progressive degradation analysis of the captured image, experimental results demonstrate that the attenuation of signal to noise ratio (SNR) versus radiation time is not obvious at the same dose rate, and the degradation is more and more serious with increasing dose rate. Additionally, the decrease rate of SNR at 20.0, 50.0 and 100.0 Gy/h is far greater than that at 1.0 and 10.0 Gy/h. Even so, we confirm that the HD industrial camera is still working at 10.0 Gy/h during the 8 h of measurements, with a moderate decrease of the SNR (5 dB). The work is valuable and can provide suggestion for camera users in the radiation field.
منابع مشابه
New Method for Analysis of image sensor to produce and evaluate the image
In this paper, a new method for evaluating CMOS image sensors based on computer modeling and analysis is introduced. Image sensors are composed of different parts, each of which has a specific effect on image quality. Circuits of image sensors can be evaluated and analyzed using circuit simulators or theoretically, but these methods cannot help to produce the final image. In order to produce th...
متن کاملAssessment of Nuclear Moisture Density Gauges at a Secondary Standard Dosimetry Laboratory in Ghana during December 2015–December 2017
Introduction: Nuclear moisture density gauges are widely used in construction industry in different countries across the world, including Ghana, on a large scale. Like all irradiating devices, the nuclear gauges should be subjected to radiation safety assessment based on radiation protection and safety principles. Regarding this, the objective of this research was to i...
متن کاملAppropriate energy window width for gamma camera [Persian]
Introduction: Scatter radiation is one of the major sources of error in nuclear medicine data processing. Different methods of scatter correction have been introduced in order to improve the quality of data. However the best method is to avoid recording of scatter photons in acquisition. The only difference between scattered and non-scattered photons is the energy. Pulse height analyzer i...
متن کاملCharacterization of digital image noise properties based on RAW data
In this paper, image noise characterization based on digital camera RAW data is studied and three different imaging technologies are compared. The three digital cameras used are Canon EOS D30 with CMOS sensor, Nikon D70 with CCD sensor and Sigma SD10 with Foveon X3 Pro 10M CMOS sensor. Due to different imaging sensor constructions, these cameras have rather different noise characteristics. The ...
متن کامل4T CMOS Image Sensor Pixel Degradation due to X-ray Radiation
-This paper presents a radiation study on the pinned photodiode (PPD) and Transfer Gate (TG) of 4T (4 Transistor) CMOS Image Sensors (CIS). The PPD and the TG are the most sensitive elements for the sensor’s dark signal. The transfer gate length has an effect on the dark current due to the electric field variation in the transfer channel and the defect generation near the overlap region between...
متن کامل