Femtosecond laser combined with non-chopping rotation phacoemulsification technique for soft-nucleus cataract surgery: a prospective study
نویسندگان
چکیده
Soft-lens cataract surgeries are becoming increasingly common for cataract surgeons and chopping the soft nucleus using conventional techniques is problematic. We introduced a femtosecond laser combined with a non-chopping rotation phacoemulsification technique for soft-nucleus cataract surgery and evaluated the safety and efficacy of using this technique. Sixty-six patients with soft-nucleus cataracts ranging from grade 1~3 were divided into 3 groups based on nuclear staging. Those groups were further divided into three subgroups: femtosecond laser pretreatment combined with a non-chopping rotation phacoemulsification technique (subgroup 1), conventional manual cataract surgery with a non-chopping rotation technique (subgroup 2) and conventional manual cataract surgery with a quick-chop technique (subgroup 3).Patients were followed up at 1, 7, and 30 days after surgery. There was an 84.6% and a 63.34% reduction in ultrasound time and cumulative dissipated energy, respectively, between the subgroup 1 and the subgroup 3; and this was associated with a 36.1% and 29.7% reduction in endothelial cell loss and aqueous flare. There were no adverse events at the follow-up times. With its reduced ultrasound energy, endothelial cell loss and aqueous flare, the femtosecond laser pretreatment combined with a non-chopping rotation technique was more efficient than conventional manual cataract surgery for soft-nucleus cataracts.
منابع مشابه
Postoperative curative effect and safety analysis of combined femtosecond laser and phacoemulsification for cataract patients
Objective: The objective of this study is to explore the influence of combined femtosecond laser and phacoemulsification on postoperative curative effect and safety on cataract patients. Method: One hundred forty-five cataract patients (148 eyes) needing operation were selected and grouped by difference in operation method: control group, 72 patients (74 eyes) were treated with traditional phac...
متن کاملOutcomes study between femtosecond laser-assisted cataract surgery and conventional phacoemulsification surgery using an active fluidics system
PURPOSE The purpose of this study was to compare intraoperative parameters between femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification using Centurion® Vision System with Active Fluidics. SETTING This study was performed at Brasília Ophthalmologic Hospital, Brasília, Federal District, Brazil. PATIENTS AND METHODS This was a prospective randomized compara...
متن کاملEffect of femtosecond laser fragmentation of the nucleus with different softening grid sizes on effective phaco time in cataract surgery.
PURPOSE To compare the effect of different fragmentation softening grids in femtosecond laser-assisted cataract surgery on effective phacoemulsification time (EPT). SETTING Ruhr University Eye Clinic, Bochum, Germany. DESIGN Prospective randomized clinical trial. METHODS The study evaluated the feasibility of using a femtosecond laser (Catalys Precision Laser System) to perform capsulotom...
متن کاملResident surgeon efficiency in femtosecond laser-assisted cataract surgery
PURPOSE Comparison of resident surgeon performance efficiencies in femtosecond laser-assisted cataract surgery (FLACS) versus conventional phacoemulsification. PATIENTS AND METHODS A retrospective cohort study was conducted on consecutive patients undergoing phacoemulsification cataract surgery performed by senior ophthalmology residents under the supervision of 1 attending physician during a...
متن کاملSafety of femtosecond laser-assisted cataract surgery performed by surgeons in training.
Femtosecond laser-assisted cataract surgery has grown in popularity among ophthalmologists as a novel technique with the potential to reduce phacoemulsification energy requirements.1,2 However, early adoption of femtosecond laser-assisted cataract surgery by experienced cataract surgeons has been associated with a significant learning curve.3 Roberts et al. reported higher complication rates in...