Use of dried spots of whole blood, plasma, and mother's milk collected on filter paper for measurement of human immunodeficiency virus type 1 burden.

نویسندگان

  • Workenesh Ayele
  • Rob Schuurman
  • Tsehaynesh Messele
  • Wendelien Dorigo-Zetsma
  • Yohannes Mengistu
  • Jaap Goudsmit
  • William A Paxton
  • Michel P de Baar
  • Georgios Pollakis
چکیده

We studied the use of dried spots of bodily fluids (plasma, whole blood, and mother's milk) on filter paper as a means of sample collection and storage for human immunodeficiency virus type 1 (HIV-1) viral load testing under stringent field conditions. Plasma placed directly in lysis buffer, which is customarily used for viral load assays, was used for comparison in all our experiments. Utilizing reconstruction experiments, we demonstrate no statistical differences between viral loads determined for plasma and mother's milk spotted on filter paper and those for the same fluids placed directly in lysis buffer. We found that the addition of whole blood directly to lysis buffer was unreliable and could not be considered a feasible option. However, viral load measurements for whole blood spotted onto filter paper correlated with plasma viral load values for both filter spots and lysis buffer (Pearson correlation coefficients, 0.7706 and 0.8155, respectively). In conclusion, dried spots of plasma, whole blood, or mother's milk provide a feasible means for the collection, storage, and shipment of samples for subsequent viral load measurement and monitoring. Virus material spotted and dried on filter paper is a good inexpensive alternative for collecting patient material to monitor the HIV-1 viral load. Measuring the HIV-1 burden from whole blood dried on filter paper provides a suitable alternative for low-technology settings with limited access to refrigeration, as can be found in sub-Saharan Africa.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitation of human immunodeficiency virus type 1 RNA in plasma by using blood dried on filter paper.

We compared whole blood dried on filter paper to the standard assay with frozen cell-free plasma for use in the quantitation of the human immunodeficiency virus RNA load in blood. RNA values from filter paper, corrected for the hematocrit, gave results comparable to those of the standard assay in terms of sensitivity and reproducibility.

متن کامل

Dried blood spots collected on filter paper: an international resource for the diagnosis and genetic characterization of human immunodeficiency virus type-1.

The collection of dried blood spots (DBS) on filter paper provides a powerful approach for the development of large-scale, population-based screening programs. DBS methods are particularly valuable in developing countries and isolated rural regions where resources are limited. Large numbers of field specimens can be economically collected and shipped to centralized reference laboratories for ge...

متن کامل

Stability of human immunodeficiency virus type 1 antibodies in whole blood dried on filter paper and stored under various tropical conditions in Kinshasa, Zaire.

The use of whole-blood spots on filter paper for the detection of antibody to human immunodeficiency virus type 1 (HIV-1) was evaluated during a 20-week period under a variety of storage environments simulating the harsh tropical field conditions in Kinshasa, Zaire. During the first 6 weeks of storage, all replicates of high- and low-titer HIV-1-positive reference samples remained positive by e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 2007