Optical magnetometer array for fetal magnetocardiography.
نویسندگان
چکیده
We describe an array of spin-exchange-relaxation-free optical magnetometers designed for detection of fetal magnetocardiography (fMCG). The individual magnetometers are configured with a small volume with intense optical pumping, surrounded by a large pump-free region. Spin-polarized atoms that diffuse out of the optical pumping region precess in the ambient magnetic field and are detected by a probe laser. Four such magnetometers, at the corners of a 7 cm square, are configured for gradiometry by feeding back the output of one magnetometer to a field coil to null uniform magnetic field noise at frequencies up to 200 Hz. We present the first measurements of fMCG signals using an atomic magnetometer.
منابع مشابه
Fetal magnetocardiography measurements with an array of microfabricated optically pumped magnetometers.
Following the rapid progress in the development of optically pumped magnetometer (OPM) technology for the measurement of magnetic fields in the femtotesla range, a successful assembly of individual sensors into an array of nearly identical sensors is within reach. Here, 25 microfabricated OPMs with footprints of 1 cm(3) were assembled into a conformal array. The individual sensors were inserted...
متن کاملMagnetocardiography with a modular spin-exchange relaxation-free atomic magnetometer array.
We present a portable four-channel atomic magnetometer array operating in the spin-exchange relaxation-free regime. The magnetometer array has several design features intended to maximize its suitability for biomagnetic measurement, specifically foetal magnetocardiography, such as a compact modular design and fibre-coupled lasers. The modular design allows the independent positioning and orient...
متن کاملOptical Magnetometer Employing Adaptive Noise Cancellation for Unshielded Magnetocardiography
This paper demonstrates the concept of an optical magnetometer for magnetocardiography. The magnetometer employs a standard Least-Mean-Squares (LMS) algorithm for heart magnetic field measurement within unshielded environment. Experimental results show that the algorithm can extract a weak heart signal from a much-stronger magnetic noise and detect the P, QRS, and T heart features and completel...
متن کاملA compact, high performance atomic magnetometer for biomedical applications.
We present a highly sensitive room-temperature atomic magnetometer (AM), designed for use in biomedical applications. The magnetometer sensor head is only 2 × 2 × 5 cm3 and is constructed using readily available, low-cost optical components. The magnetic field resolution of the AM is <10 fT Hz–1/2, which is comparable to cryogenically cooled superconducting quantum interference device (SQUID) m...
متن کاملReproducibility and reliability of fetal cardiac time intervals using magnetocardiography.
We investigated several factors which may affect the accuracy of fetal cardiac time intervals (CTI) determined in magnetocardiographic (MCG) recordings: observer differences, the number of available recording sites and the type of sensor used in acquisition. In 253 fetal MCG recordings, acquired using different biomagnetometer devices between the 15th and 42nd weeks of gestation, P-wave, QRS co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 37 12 شماره
صفحات -
تاریخ انتشار 2012