Pulsed electron avalanche knife (PEAK) PlasmaBlade™ in pacemaker and defibrillator procedures
نویسندگان
چکیده
BACKGROUND The pulsed electron avalanche knife (PEAK) PlasmaBlade™ is an innovative electrosurgical device that uses a novel technology to cut tissues. It has been proven to be safe and feasible in ear, nose, and throat surgery, but there are only limited data concerning the use of PlasmaBlade™ instead of conventional electrocautery in cardiac implantable electronic device (CIED) procedures except for generator replacements. METHODS We conducted a retrospective, single-center study with patients undergoing CIED surgery at our center between December 2015 and March 2017 and evaluate the feasibility and the clinical outcome of the PlasmaBlade™. RESULTS 282 patients (mean age 70.7 ± 12.9 years; 65.6% male) were included, of which 119 (42.2%) underwent pacemaker implantation, 95 (33.7%) implantable cardioverter defibrillator implantation, and 68 (24.1%) received a generator replacement. At the time of the procedure, 55 patients (19.5%) were on dual antiplatelet therapy, and 109 (38.7%) patients were on oral anticoagulation (30.5% vitamin K antagonists, 8.2% novel oral anticoagulants). The overall perioperative complication rate was 3.9%. Device-pocket hematoma occurred in 9 patients (3.2%) requiring further surgery. No lead damage was seen within a follow-up of 6 months. One patient presented with device-pocket infection 2.9 months after implantation of a cardiac resynchronization therapy defibrillator requiring CIED system extraction. CONCLUSIONS Replacing conventional electrocautery by PlasmaBlade™ for CIED procedures is feasible with a moderate rate of perioperative complications compared to the literature. Studies comparing the PlasmaBlade™ with conventional electrocautery are necessary to investigate whether PlasmaBlade™ offers an additional benefit over conventional electrocautery.
منابع مشابه
Video Nasoendoscopic-Assisted Transoral Adenoidectomy with the PEAK PlasmaBlade: A Preliminary Report of a Case Series
Objectives. The primary objective for this study is to evaluate the advantages, disadvantages, surgical applicability, and outcome of the pulsed electron avalanche knife (PEAK) PlasmaBlade in transoral adenoidectomy under direct visualization using video nasoendoscopy. Patients and Methods. In this series, six cases of adenoid hypertrophy showing varying clinical presentations in relation to it...
متن کاملAnterior capsulotomy with a pulsed-electron avalanche knife.
PURPOSE To evaluate a new pulsed-electron avalanche knife design for creating a continuous curvilinear capsulotomy (CCC) and compare the CCC with a mechanical capsulorhexis. SETTING Department of Ophthalmology, Stanford University, Stanford, California, USA. METHODS In this study, CCCs were created in freshly enucleated bovine eyes and in rabbit eyes in vivo. The cutting velocity was adjust...
متن کاملPulsed electron avalanche knife in vitreoretinal surgery.
PURPOSE To evaluate the advantages, disadvantages, safety, and surgical applicability of the pulsed electron avalanche knife (PEAK-fc), a new electrosurgical knife for "cold" and tractionless cutting, in vitreoretinal surgery. PEAK-fc is equipped with an integrated fiberoptic that makes bimanual procedures in intraocular surgery possible. METHODS A prospective consecutive trial of 18 eyes in ...
متن کاملPrecision and safety of the pulsed electron avalanche knife in vitreoretinal surgery.
BACKGROUND We have developed a new surgical instrument, called the pulsed electron avalanche knife (PEAK; Carl Zeiss Meditec, Jena, Germany), for precise, "cold," and tractionless dissection of tissue in liquid media. OBJECTIVE To evaluate the 3-dimensional damage zone induced by the PEAK compared with 2 other standard intraocular surgical instruments, diathermy and retinal scissors. METHOD...
متن کاملPulsed electron avalanche knife for capsulotomy in congenital and mature cataract.
The pulsed electron avalanche knife (PEAK-fc, Carl Zeiss Meditec) is an electrosurgical cutting device that allows precise "cold" and traction-free tissue dissection. We describe its applicability and safety for anterior capsulotomy in a child with congenital cataract and an adult patient with mature cataract. The PEAK-fc was set at a voltage of 600 V and a pulse repetition rate of 80 Hz. Anter...
متن کامل