Clinical implication of interface pressure for a new prosthetic suspension system
نویسندگان
چکیده
BACKGROUND Prosthesis suspension systems can alter the distribution of pressure within the prosthetic socket. This study evaluates a new suspension system for lower limb prostheses, and aims to compare the interface pressure and amputees' satisfaction with the new system compared with a common prosthetic suspension system (pin/lock). METHODS Ten transtibial amputees walked at a self-selected speed on a level ground with two different suspension systems, namely the pin/lock and HOLO system. The interface pressure was measured using the F-socket transducers at the proximal, middle and distal sites of residual limb. Furthermore, subjective feedback was logged to compare two systems. RESULTS The pressure was significantly higher at the proximal and distal areas with the pin/lock suspension system during the swing phase of gait (P<0.05). Subjective feedback also showed traction at the stump with the pin/lock system. There were no significant differences in the pressure applied to the mid-anterior and mid posterior stump for both suspension systems. However, the lateral and medial sides exhibited higher pressure with the new system during stance phase. CONCLUSIONS The intention of this study was to deepen understanding on the effect of suspension system on the load distribution over the residual limb. The new coupling system was proved compatible with the pin/lock system in terms of suspending the leg and amputee's satisfaction. On the other hand, the HOLO system could distribute the pressure more uniformly over the residual limb.
منابع مشابه
An experimental study of the interface pressure profile during level walking of a new suspension system for lower limb amputees.
BACKGROUND Different suspension systems that are used within prosthetic devices may alter the distribution of pressure inside the prosthetic socket in lower limb amputees. This study aimed to compare the interface pressure of a new magnetic suspension system with the pin/lock and Seal-In suspension systems. METHODS Twelve unilateral transtibial amputees participated in the study. The subjects...
متن کاملDevelopment of an Air Pneumatic Suspension System for Transtibial Prostheses
The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air ...
متن کاملReview of the Socket Design and Interface Pressure Measurement for Transtibial Prosthesis
Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressu...
متن کاملA study of interface pressures in the below-knee prosthesis (physiological suspension: an interim report).
Since its inception, the Prosthetics Research Study has attempted to maximize retention and stabilization of residual limb musculature in the below-knee amputation . Combined with myoplastic technique, Immediate Postoperative Prosthetic fitting, training of residual limb muscles, and an appropriate definitive prosthesis, an effective, functional end organ is achieved. Clinical observation has s...
متن کاملInterface pressure in transtibial socket during ascent and descent on stairs and its effect on patient satisfaction.
BACKGROUND Transtibial amputees encounter stairs and steps during their daily activities. The excessive pressure between residual limb/socket may reduce the walking capability of transtibial prosthetic users during ascent and descent on stairs. The purposes of the research were to evaluate the interface pressure between Dermo (shuttle lock) and Seal-In X5 (prosthetic valve) interface systems du...