Cooling during exercise in temperate conditions: impact on performance and thermoregulation.

نویسندگان

  • T M H Eijsvogels
  • C C W G Bongers
  • M T W Veltmeijer
  • M H Moen
  • M Hopman
چکیده

Exercise-induced increase in core body temperature may lead to the development of hyperthermia (>40.0°C) and/or decreased performance levels. This study examined the effects of wearing a cooling vest during a 5-km time trial on thermoregulatory responses and performance. 10 male masters athletes (42±10 years) performed a 5-km time trial on a motorized treadmill in a climate chamber (25°C, 55% relative humidity) with and without a cooling vest. Split times, heart rate, core-, skin- and cooling vest temperature were measured every 500 m. Subjects also rated thermal comfort and level of perceived exertion. The cooling vest significantly decreased heart rate (p<0.05), decreased skin temperature (p<0.001) and improved thermal comfort (p<0.005) during the time trial. Time to finish the 5-km time trial and pacing strategy did not differ between the control (1 246±96 s) and cooling vest condition (1 254±98 s, p=0.85). Additionally, thermoregulatory responses, maximum core body temperature and level of perceived exertion were not different across conditions (p=0.85, p=0.49, p=0.11, respectively). In conclusion, we demonstrated that wearing a cooling vest during exercise improves thermal comfort but does not enhance performance or decrease core body temperature in male masters athletes under temperate ambient conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of short-term heat acclimation with permissive dehydration on thermoregulation and temperate exercise performance.

We examined the effect of short-term heat acclimation with permissive dehydration (STHADe) on heat acclimation (HA) and cycling performance in a temperate environment. Ten trained male cyclists [mean (SD) maximal oxygen uptake: 63.3(4.0) mL/kg/min; peak power output (PPO): 385(40) W; training: 10 (3) h/week] underwent a STHADe program consisting of 5 days of exercise (maximum 90 min/day) in a h...

متن کامل

The Effect of Intermittent Head Cooling on Aerobic Performance in the Heat.

Thermoregulation is critical for athletes, particularly those for those who must perform in the heat. Most strategies aimed at reducing heat stress have cooled participants before or during activity. The objective of this study is to investigate whether seven minutes of head cooling applied between bouts of aerobic exercise in hot (35 ± 1.0 °C) and dry (14.68 ±4.29% rh) environmental conditions...

متن کامل

Effect of a moderate caffeine dose on endurance cycle performance and thermoregulation during prolonged exercise in the heat.

OBJECTIVES This study investigated the influence of a moderate caffeine dose on endurance cycle performance and thermoregulation during prolonged exercise in high ambient temperature. DESIGN Double-blind cross-over study. METHODS Eight healthy, recreationally active males (mean±SD; age: 22±1 years; body mass: 71.1±8.5kg; VO2peak: 55.9±5.8mLkg-1min-1; Wmax: 318±37W) completed one VO2peak tes...

متن کامل

The effects of head cooling on endurance and neuroendocrine responses to exercise in warm conditions.

The present study investigated the effects of head cooling during endurance cycling on performance and the serotonergic neuroendocrine response to exercise in the heat. Subjects exercised at 75 % VO(2max) to volitional fatigue on a cycle ergometer at an ambient temperature of 29+/-1.0 degrees C, with a relative humidity of approximately 50 %. Head cooling resulted in a 51 % (p<0.01) improvement...

متن کامل

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of sports medicine

دوره 35 10  شماره 

صفحات  -

تاریخ انتشار 2014