Intrathecal catheter-syringe adaptor for short-term intrathecal analgesia with an externalized pump: a case report.
نویسندگان
چکیده
BACKGROUND In most patients, cancer pain is effectively treated with conservative medical management consisting of oral and/or transdermal analgesics. Cancer patients tend to fail conservative medical management near the end of their life expectancy, thus requiring alternative routes of analgesia such as intravenous, epidural, or intrathecal. The intrathecal route provides the most effective analgesia due to the close proximity of the opioid receptors in the spinal cord. Though there are many techniques that exist for intrathecal drug delivery, complications can limit effectiveness such as infection, bleeding, cerebrospinal fluid (CSF) leaks, post-dural puncture headaches (PDPH), pump and/or catheter malfunctions, or limitations of technical expertise. Therefore, an important goal in palliative cancer pain therapy is to use equipment that is going to have the fewest number of complications and will be the most familiar to the health care providers. We describe the combination of the Medtronic Indura 1P catheter, which has the least catheter-related complications and can be used with any external drug infusion pump. These are regular infusion pumps that the health care workers are familiar with so they can provide excellent and efficient service to the patient. METHODS In an operating room, the intrathecal catheter was placed using sterile technique under fluoroscopic guidance. The epidural space was identified with loss of resistance technique. Then the introducer needle (supplied in the Indura 1P catheter kit) was advanced until free-flowing CSF was obtained. The spinal catheter was advanced into the intrathecal space through the introducer needle to lumbar 2-3 level. The catheter was tunneled subcutaneously 10 cm lateral to the catheter exit site. A syringe filling device was inserted into the catheter opening and was secured with silk suture. A luer lock syringe was attached to the syringe filling device and CSF was aspirated. The syringe filling device was capped and later attached to an external drug infusion pump. RESULTS We report the successful use of the Medtronic Indura 1P, one piece intrathecal catheter, connected to the external drug pump for a 3 week period in a patient with metastatic cervical cancer for palliative pain control. LIMITATIONS Case report only. CONCLUSION This technique is simple to perform by pain specialists. The catheter modification allows the use of the Medtronic intrathecal catheter with standard external drug infusion pumps. This facilitates the patient's care in the hospice setting.
منابع مشابه
Intrathecal analgesia in patients with cancer pain--an audit in a tertiary institution.
INTRODUCTION Cancer pain is one of the most frequently encountered pain syndromes. With the application of the World Health Organization analgesic ladder, adequate analgesia is achieved in 75% to 90% of patients. The remaining patients suffer from intractable pain requiring intrathecal analgesia. The aim of this study was to retrospectively analyse the pain intensity before and after intratheca...
متن کاملAbstract # 218: Ultrasound Guided Epidural Analgesia for Labour in a Patient with an Intrathecal Baclofen Pump
218 Ultrasound Guided Epidural Analgesia for Labour in a Patient with an Intrathecal Baclofen Pump Abstract Type: Case Report/Case Series Manasi Badve, M.D.; Tanmay Shah, M.D.; Jeremy Rice, D.O.; Manuel Vallejo, M.D. Magee-Womens Hospital of UPMCType: Case Report/Case Series Manasi Badve, M.D.; Tanmay Shah, M.D.; Jeremy Rice, D.O.; Manuel Vallejo, M.D. Magee-Womens Hospital of UPMC Intrathecal ...
متن کاملContinuous caudal epidural analgesia in a patient with an implanted intrathecal baclofen pump
Introduction: The use of epidural analgesia in patients with implanted intrathecal delivery devices is somewhat controversial. Major concerns include the risk of damaging the intrathecal catheter, the risk of infection, and the potential for interaction between the epidurally-administered and the intrathecally-delivered medication. In children with cerebral palsy, intrathecal administration of ...
متن کاملDecrease in the incidence of post-dural puncture headache: maintaining CSF volume.
The incidence of epidural needle-induced post-dural puncture headache (PDPH) in parturients following dural puncture with a large bore (18-gauge) needle has been reported to range 76-85%. We describe seven cases in which the performance of epidural anesthesia in parturients was complicated by an unintentional dural puncture with an 18-gauge epidural needle. In all seven cases, the unintentional...
متن کاملRetraction of an intrathecal baclofen infusion catheter following suprapubic cystotomy: a case report.
INTRODUCTION Intrathecal baclofen, administered via a Baclofen pump, is used for patients with spasticity. We report here a case of intrathecal catheter retraction following surgery. CASE REPORT A male patient with adrenoleukodystrophy and a baclofen pump implant was admitted to the urology department with bladder stones. A transurethral cystolithotripsy and a suprapubic cystotomy were perfor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Pain physician
دوره 13 2 شماره
صفحات -
تاریخ انتشار 2010