Application of a picrolonate ion-selective electrode to the assay of calcium and piperazine in pharmaceuticals and serum.
نویسندگان
چکیده
The construction and some analytical applications of a liquid picrolonate (Picrl-) ion-selective electrode based on the tris(phenanthrolinato)iron(II) (ferroin) picrolonate salt, dissolved in 2-nitrotoluene, are described. The liquid membrane electrode exhibits a rapid and almost Nernstian response to picrolonate anions in the concentration range from 5 x 10(-2) to 5 x 10(-2) mol l-1. The response is virtually unaffected by pH changes in the range 3-10. Major interferents are picrates, 4-nitrophenolates, 3,5-dinitrosalicylates and 2,4-dinitrophenolates. In analytical applications direct potentiometric methods for the determination of picrolonates and indirect methods for the determination of calcium and piperazine are described. Calcium in the ranges 4-24 and 50-90 mg l-1, under specified experimental conditions, can be determined with mean relative errors of 1.1 and 1.4%, respectively. The method is applicable to soluble samples, pharmaceuticals and industrial and real human serum. Piperazine in the ranges 1-10 and 13-20 mg can be determined with a mean relative error of 1.2% in soluble salts and pharmaceutical formulations, respectively. An accuracy of better than 1.5% and a reproducibility (relative standard deviation) of 0.1% were achieved in the analysis of pharmaceutical products.
منابع مشابه
An electrode immobilized in a graphite matrix with ion pair complex for the determination of diclofenac in pharmaceuticals
A simple, precise, rapid and low-cost potentiometric method for diclofenac determination in pharmaceuticals is proposed. A new diclofenac-sensitive electrode was constructed by incorporating the diclofenac ion pair complex with butyl rhodamine B into graphite matrix. The electrode exhibited a linear response over the concentration range of 1 × 10-4 – 5 × 10-2 mol L-1, a detection limit of 3.9×1...
متن کاملApplication of a dioxime-PVC electrode to potentiometric studies of Cr(III) ion
A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...
متن کاملCu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone
In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...
متن کاملChromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier
A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...
متن کاملApplication of a New Macrocyclic -PVC Electrode to Potentiometric Studies of Fe(III) Ion
A PVC membrane Fe(III) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.The electrode exhibits a good potentiometric response for Fe(III) over a wideconcentration range 1.0×10-4 to 1.0×10-1M with a slope 19.4±0.5 mV/decade a and a working pHrange of 6.5-9.0. It has a fast response time ≤30s.The best performance was observed with themembrance having the 30....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 119 7 شماره
صفحات -