Determination of N,N-dimethylaminoethyl chloride and the dimethylaziridinium ion at sub-ppm levels in diltiazem hydrochloride by LC-MS with electrospray ionisation.

نویسندگان

  • C R Lee
  • M Hubert
  • C N Van Dau
  • D Peter
  • A M Krstulovic
چکیده

An LC-MS method is described for the determination of the synthetic reagent N,N-dimethylaminoethyl chloride (DMC) in the drug substance diltiazem hydrochloride, for which the permissible limit is not more than 1 ppm (microgram g-1). The N,N-dimethylaziridinium ion (DMA), the reactive intermediate formed by cyclisation of DMC, is also detected. A column switching arrangement is used: diltiazem hydrochloride is trapped on a reversed-phase HPLC column, and the polar analytes are separated by ion exchange chromatography. Ionisation is effected by positive-ion electrospray, and the quadrupole filter mass spectrometer is operated in the selected ion recording mode. The detection limit (peak height-to-baseline noise ratio = 3) for DMC varies from day to day in the range < 0.05 to 0.1 ppm. The response for DMC is linear (r > 0.999) over the concentration range 0.2-10 ppm, and the repeatability is better than 7% (relative standard deviation) at 1.0 ppm. Concentrations of DMC in diltiazem hydrochloride from the manufacturing facility under study ranged from undetectable to about 0.07 ppm. An indirect TLC method has been published for the determination of DMC in mepyramine maleate, but it lacks the necessary sensitivity and specificity. The LC-MS method presented is direct, straightforward and suitable for routine use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Method validation of clonidine hydrochloride in human plasma by LC-MS technique

A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile&ndash;water 60:40 (v/v), and 0.2% formic acid 20 &micro;L of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm&times;30 m...

متن کامل

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Method validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.

Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 125 7  شماره 

صفحات  -

تاریخ انتشار 2000