A multi‐institutional study for tolerance and action levels of IMRT dose quality assurance measurements in Korea
نویسندگان
چکیده
The purpose of this study was to suggest tolerance levels for IMRT DQA measurements using confidence limits determined by a multi-institutional study in Korea. Ten institutions were grouped into LINAC (seven linear accelerators) and TOMO (three tomotherapy machines). The DQA processes consisted of point (high- and low-dose regions) and planar (per-field and composite-field) dose measurements using an ion chamber and films (or 2D detector array) inserted into a custom-made acryl phantom (LINAC) or a cheese phantom (TOMO). The five mock structures developed by AAPM TG-119 were employed, but the prostate as well as the H&N structures were modified according to Korean patients' anatomy. The point measurements were evaluated in a ratio of measured and planned doses, while the planar dose distributions were assessed using two gamma criteria of 2 mm/2% and 3 mm/3%. The confidence limit (|mean + 1.96 σ|) for point measurements was determined to be 3.0% in high-dose regions and 5.0% in low-dose regions. The average percentage of points passing the gamma criteria of 2 mm/2% and 3mm/3% for per-field measurements was 92.7 ± 6.5% and 98.2 ± 2.8%, respectively. Thus, the corresponding confidence limit was 79.1% and 92.7%, respectively. The gamma passing rate averaged over all mock tests and institutions for composite-field measurements was 86.1 ± 6.5% at 2 mm/2% and 95.3 ± 3.8% at 3 mm/3%, leading to the confidence limit of 73.3% and 87.9%, respectively. There was no significant difference in the tolerance levels of point dose measurements between LINAC and TOMO groups. In spite of the differences in mock structures and dosimetry tools, our tolerance levels were comparable to those of AAPM and ESTRO guidelines.
منابع مشابه
Confidence limits for patient‐specific IMRT dose QA: a multi‐institutional study in Korea
This study aims to investigate tolerance levels for patient-specific IMRT dose QA (DQA) using the confidence limits (CL) determined by a multi-institutional study. Eleven institutions participated in the multi-institutional study in Korea. A total of 155 DQA measurements, consisting of point-dose differences (high- and low-dose regions) and gamma passing rates (composite and per-field) for IMRT...
متن کاملQuantitative measurements for entrance and exit radiation dose confirmation for cancer patients: An analysis of large cohort of patients
Background: The success of radiation therapy depends on accurate dose delivery to the target. Diode in vivo measurement of entrance and exit dose is a valuable quality assurance (QA) tool to ensure accurate dose delivery. Materials and Methods: This study was performed at BINO Cancer Hospital, Bahawalpur. Entrance and exit dose measurements were done with p-type diode for various types of canc...
متن کاملThree-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT
Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...
متن کامل3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk
Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...
متن کاملمقایسه عملکرد فیلم گف کرومیک EBT3و فانتوم Delta4® در تکنیک IMRT محیط ناهمگن قفسه سینه
Introdution: In advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT), the quality assurance (QA) is essential. This study aimed to compare the performance between GafchromicTM EBT3 film and Delta4® phantom (2D and 3D) in heterogeneous chest phantom using IMRT technique. Methods: In this experimental study, two IMRT plans (A and B) were prepared for radiothe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2013