Torque capacity of metal and polycarbonate brackets with and without a metal slot.

نویسندگان

  • Winfried Harzer
  • Christoph Bourauel
  • Henner Gmyrek
چکیده

The aim of the present study was to investigate slot deformation and the equivalent torque capacity of polycarbonate brackets with and without a metal slot in comparison with those of a metal bracket. For this purpose, the expansion characteristics and, in a further investigation, the labial crown torque of an upper central incisor, were measured in a simulated intra-oral clinical situation, using the orthodontic measuring and simulation system (OMSS). Three types of bracket with a 0.018 inch slot were tested: polycarbonate Brillant without a metal slot, Elegance with a metal slot and the metal bracket, Mini-Mono. For testing purposes the brackets were torqued with 0.016 x 0.022 inch (0.41 x 0.56 mm) and 0.018 x 0.022 inch (0.46 x 0.56 mm) ideal stainless steel archwires. In the activating experiments, significantly higher torque losses and lower torquing moments were registered with both rectangular archwires with the polycarbonate brackets than with the metal bracket. In the simulation tests, significantly higher torquing moments were registered with the metal bracket than with the polycarbonate brackets. The values for the Elegance bracket were between those of the Mini-Mono and Brillant brackets. The OMSS model approximates the clinical situation, with the torque loss being notably higher than in the in vitro activating experiments. This is due to the adjacent teeth giving the archwire additional play. In addition, the torquing process may twist the archwire, resulting in subsidiary forces. On the basis of the present results, all three brackets can be recommended for torquing. However, in view of the high torque losses, the torques programmed in the straightwire technique must be seen as questionable. Data should be provided by the manufacturer on the bending to be expected in polycarbonate brackets, which has to be offset by additional torque, or the bracket torque should be omitted from the technical specifications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Torque expression of self-ligating brackets compared with conventional metallic, ceramic, and plastic brackets.

The purpose of this research was to investigate the torque capacity of active and passive self-ligating brackets compared with metallic, ceramic, and polycarbonate edgewise brackets. Six types of orthodontic brackets were included in the study: the self-ligating Speed and Damon2, the stainless steel (SS), Ultratrimm and Discovery, the ceramic bracket, Fascination 2, and the polycarbonate bracke...

متن کامل

Evaluation of mechanical properties of esthetic brackets

Plastic brackets, as well as ceramic brackets, are used in various cases since they have excellent esthetics. However, their mechanical properties remain uncertain. The purpose of this study was to determine how deformation and stress distribution in esthetic brackets differ among materials under the same wire load. Using the digital image correlation method, we discovered the following: (1) th...

متن کامل

Assessment of dimensional accuracy of preadjusted metal injection molding orthodontic brackets

BACKGROUND the aim of this study is to evaluate the dimensional accuracy of McLaughlin, Bennett, and Trevisi (MBT) brackets manufactured by two different companies (American Orthodontics and Ortho Organizers) and determine variations in incorporation of values in relation to tip and torque in these products. MATERIALS AND METHODS In the present analytical/descriptive study, 64 maxillary right...

متن کامل

Microleakage under Orthodontic Metal Brackets Bonded with Three Different Bonding Techniques with/without Thermocycling

Introduction: The aim of this study was to compare the microleakage of beneath the orthodontic brackets bonded with 3 different bonding techniques and evaluate the effect of thermocycling. Methods: One hundred and twenty premolars were randomly divided into 6 groups, received the following treatment: group 1: 37% phosphoric acid gel+Unite primer+Unite adhesive, group 2: 37% phosphoric acid gel+...

متن کامل

Fabrication and characterization of polycarbonate/titanium oxide nanotubes mixed matrix membranes for efficient removal of cadmium and copper from aqueous solution

In this study, novel polycarbonate-titanium oxide nanotubes (PC-TNT) ultrafiltration mixed matrix membranes (MMMs) were fabricated for decontamination of Cd2+ and Cu2+ metal ions from aqueous solution. The weight percent of TNTs in the polycarbonate membrane matrix was changed from 0 to 15. The synthesized neat PC membrane and PC-TNTs MMMs were characterized with respect to structural morpholog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 26 4  شماره 

صفحات  -

تاریخ انتشار 2004