Standard values for gas-perfusion manometry of the esophagus
نویسندگان
چکیده
The manometry with water-perfused or solid-state catheters is the predominant diagnostic procedure to detect motility disorders of the esophagus. Another method is the manometry using gas-perfused catheters. Although the high-resolution manometry is the method of first choice, the conventional manometry with helium has some advantages: the simple and hygienically unproblematic use and the absence of any artefacts by the perfusion medium compared with water-perfusion, and the considerably lower costs compared with the solid-state catheters. Every method has own normal values because of the specific pressure transmission and the design of the catheter probes. To our knowledge, normal values for gas-perfusion manometry of the esophagus have not yet been published.The esophageal manometry with helium-perfused catheters was performed in 30 healthy volunteers. The main parameters of the esophageal motility and the lower esophageal sphincter were analyzed by liquid and bolus-like swallows and compared with the previous published values in other manometric procedures.The values of the motility in the distal esophagus are consistent; the pressure of the lower esophageal sphincter is generally lower than with other methods. The distal wave amplitude and the propagation velocity are significant higher in the distal esophagus than in the middle. The perfusion medium is well tolerated by the investigated volunteers.
منابع مشابه
Relationship between esophageal clinical symptoms and manometry findings in patients with esophageal motility disorders: a cross-sectional study
Background: Manometry is the gold-standard diagnostic test for motility disorders in the esophagus. The development of high-resolution manometry catheters and software displays of manometry recordings in color-coded pressure plots have changed the diagnostic assessment of esophageal disease. The diagnostic value of particular esophageal clinical symptoms among patients suspected of esophageal m...
متن کاملHigh-resolution esophageal manometry: a time motion study.
INTRODUCTION High-resolution manometry (HRM) of the esophagus is a new technique that provides a more precise assessment of esophageal motility than conventional techniques. Because HRM measures pressure events along the entire length of the esophagus simultaneously, clinical procedure time should be shorter because less catheter manipulation is required. According to manufacturer advertising, ...
متن کاملComparison of Investigation Modalities for Evaluation of Esophageal Peristaltic Function
We reviewed the recent literature concerning investigations of esophageal peristaltic function. The gold standard for the assessment of esophageal peristaltic function is manometry with pH monitoring. Even with this investigation modality, however, we are in fact doing no more than estimating esophageal peristaltic function from the manometry and pH results. With esophageal fluoroscopy and scin...
متن کاملMultichannel intraluminal impedance accurately detects fasting, recumbent reflux events and their clearing.
Multichannel intraluminal impedance (MII) is a new diagnostic test for gastroesophageal reflux disease (GERD). The objective of this report is to determine the accuracy of MII in detecting individual reflux events (REs) identified by pH probe and manometry, as well as their clearing in patients with severe GERD compared with normal volunteers. Ten severe GERD patients and 10 normal volunteers u...
متن کاملInvestigation of pharyngeal swallowing function using high-resolution manometry.
OBJECTIVES/HYPOTHESIS This study aimed to demonstrate the feasibility of a novel high-resolution manometry system, and to establish normal values of swallowing pressures along the velopharynx and upper esophagus. STUDY DESIGN Prospective study. METHODS Thirty-three asymptomatic adult Japanese controls were studied. A solid-state high-resolution manometry assembly with 36 circumferential sen...
متن کامل