3 - D photon treatment planning using FFT convolution

نویسندگان

  • Eugene Wong
  • Yunping Zhu
  • Jake Van Dyk
چکیده

A theory is presented on dose calculations in inhomogeneous media that takes advantage of fast Fourier transform (FFT) convolution for practical 3-D treatment planning using photon beams. We derived a new correction dose formula which corrects the dose deposited by the Compton rst scattered photons due to the presence of inhomogeneities. We justiied theoretically why the convolution primary dose formula for homogeneous water medium continues to be valid for inhomogeneous media. We veriied our results by comparing to measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code

Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...

متن کامل

Dosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields

Background: The dosimetric performance of Eclipse 6.5 three dimensional treatment planning system (3DTPS) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of American Association for Physicists in Medicine Task Group 53. Materials and Methods: The calculations were performed by the 3DTPS for symmetric as well as asymmetric fields for standar...

متن کامل

بررسی میزان دقت الگوریتم‌های سیستم طراحی درمان رادیوتراپی در پیش‌بینی دز پروتز مفصل ران با استفاده از شبیه سازی مونت‌‌کارلو

  Abstract   Background : Beam-hardening artifacts in CT image set of patient with a hip prosthesis cause difference between dose distributions resulted by treatment planning system (TPS) algorithms and actual dose distribution in patient body. In this study, dose distributions of TPS algorithms were compared with the results of Monte Carlo simulations of Titanium and Steal as a h...

متن کامل

Implementation of 3-D Anisotropy Corrected Fast Fourier Transform Dose Calculation around Brachytherapy Seeds

A routine dose computation around brachytherapy seeds employing the Fast Fourier Transform (FFT) has been demonstrated and likened to dose computations in a similar field based on the TG43 recommendations. In applying the FFT convolution model to dose computation, a dose convolution kernel which takes into consideration the anisotropy of the dose distribution around a brachytherapy source in th...

متن کامل

Dosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study

Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -