Validation of Aura Microwave Limb Sounder OH measurements with Fourier Transform UltraViolet Spectrometer total OH column measurements at Table Mountain, California

نویسندگان

  • Shuhui Wang
  • Herbert M. Pickett
  • Thomas J. Pongetti
  • Ross Cheung
  • Yuk L. Yung
  • Changsub Shim
  • Qinbin Li
  • Timothy Canty
  • Ross J. Salawitch
  • Kenneth W. Jucks
  • Brian Drouin
  • Stanley P. Sander
چکیده

[1] The first seasonal and interannual validation of OH measurements from the Aura Microwave Limb Sounder (MLS) has been conducted using ground-based OH column measurements from the Fourier Transform Ultra-Violet Spectrometer (FTUVS) over the Jet Propulsion Laboratory’s Table Mountain Facility (TMF) during 2004–2007. To compare with FTUVS total column measurements, MLS OH vertical profiles over TMF are integrated to obtain partial OH columns above 21.5 hPa, which covers nearly 90% of the total column. The tropospheric OH and the lower stratopheric OH not measured by MLS are estimated using GEOS (Goddard Earth Observing System)-Chem and a Harvard 2-D model implemented within GEOS-Chem, respectively. A number of field observations and calculations from a photochemical box model are compared to OH profiles from these models to estimate the variability in the lower atmospheric OH and thus the uncertainty in the combined total OH columns from MLS and models. In general, the combined total OH columns agree extremely well with TMF total OH columns, especially during seasons with high OH. In winter with low OH, the combined columns are often higher than TMF measurements. A slightly weaker seasonal variation is observed by MLS relative to TMF. OH columns from TMF and the combined total columns from MLS and models are highly correlated, resulting in a mean slope of 0.969 with a statistically insignificant intercept. This study therefore suggests that column abundances derived from MLS vertical profiles have been validated to within the mutual systematic uncertainties of the MLS and FTUVS measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

OH column abundance over Table Mountain Facility, California: AMPM diurnal asymmetry

[1] Observations of the OH column abundance have been made by the Fourier Transform Ultraviolet Spectrometer at the JPL Table Mountain Facility (TMF) near Los Angeles since July 1997. In the January 1998– December 2003 data set we used five OH lines to derive the OH column abundance in the atmosphere. This data set was used to quantify the OH morning/afternoon asymmetry (AMPMDA). An analysis of...

متن کامل

Airborne Fourier transform spectrometer observations in support of EOS Aura validation

[1] Nearly coincident observations of HNO3, HCl, N2O, and H2O in the vicinity of the northern polar vortex during the NASA Polar Aura Validation Experiment (PAVE) in January and February 2005 have shown reasonably good agreement between aircraft-borne infrared spectrometer results and results from High Resolution Dynamics Limb Sounder (HIRDLS), Microwave Limb Sounder (MLS), and Tropospheric Emi...

متن کامل

OH column abundance over Table Mountain Facility, California: Intraannual variations and comparisons to model predictions for 19972001

[1] Measurements of the OH column abundance over the Jet Propulsion Laboratory’s Table Mountain Facility (TMF) have been made since July 1997 at 10 –80 solar zenith angle using a Fourier transform ultraviolet spectrometer. The measured OH column at any solar zenith angle is typically larger in the afternoon than in the morning. The variations observed in the OH column abundance appear to result...

متن کامل

Validation of Tropospheric Emission Spectrometer (TES) measurements of the total, stratospheric, and tropospheric column abundance of ozone

[1] The Tropospheric Emission Spectrometer (TES) is an infrared, high-resolution Fourier transform spectrometer which was launched onboard NASA’s Aura satellite in 2004 and is providing global, vertically resolved measurements of ozone in the troposphere. TES version 2 (V002) data profiles have been validated in the troposphere and lower stratosphere by way of comparison to ozonesondes and airc...

متن کامل

High-Resolution Fourier-Transform Ultraviolet-Visible Spectrometer for the Measurement of Atmospheric Trace Species: Application to OH.

A compact, high-resolution Fourier-transform spectrometer for atmospheric near-ultraviolet spectroscopy has been installed at the Jet Propulsion Laboratory's Table Mountain Facility (34.4 degrees N, 117.7 degrees W, elevation 2290 m). This instrument is designed with an unapodized resolving power near 500,000 at 300 nm to provide high-resolution spectra from 290 to 675 nm for the quantification...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008