A novel poly(vinyl chloride) matrix membrane sensor for batch and flow-injection determinations of thiocyanate, cyanide and some metal ions.
نویسندگان
چکیده
A poly(vinyl chloride) matrix membrane sensor for the selective determination of thiocyanate has been developed based on the use of copper(II)-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex (Cu-PADAP) as a novel charged carrier, and o-nitrophenyloctyl ether (o-NPOE) as a solvent mediator. The sensor displays a significantly enhanced response towards SCN(-) ions over the concentration range 7.0 x 10(-6) to 1.0 x 10(-2) mol L(-1) with a detection limit of 5.6 x 10(-6) mol L(-1) and a calibration slope of -57.5 +/- 0.5 mV decade(-1). The sensor exhibits a long life-span, long-term stability, high reproducibility, and a fast response time. The selectivity coefficients of some anions were calculated using the separate solutions method, and found to be in the following order: SCN(-) > ClO(4)(-) > I(-) > Sal(-) > NO(2)(-) > Br(-) > NO(3)(-) = CH(3)COO(-) > Cl(-) > SO(4)(2-) = PO(4)(3-). The effects of the pH and ionic membrane additives (e.g. tridodecylmethylammonium chloride, TDMAC and potassium tetrakis[bis(3,5-trifluoromethyl)phenyl] borate, KTFPB) were examined. The sensor was used for the determination of SCN(-) ions in saliva and urine samples collected from some smoker and non-smoker donors. The developed sensor was also applied to determine the cyanide content in electroplating waste water samples after its conversion into thiocyanate. The application of the sensor to monitor the potentiometric titration of Ag(+) and Hg(2+) using SCN(-) resulted in sharp inflection breaks at the equivalent points. The data obtained using the proposed sensor correlate very well with results collected using the standard methods of thiocyanate, cyanide and metal analysis.
منابع مشابه
Polymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions
Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...
متن کاملChromium (III) ion selective electrode based on di(benzylamino)glyoxime
A new poly(vinylchloride) membrane sensor for Cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. The electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with aNernstian slope of 20.3 ± 0.5 mV per decade and a detection limit of 2×10-7. It has a fast responsetime of
متن کاملComparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques
Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
متن کاملFlow-through Bulk Optode for Spectrophotometric Determination of Thiocyanate and Its Application to Water and Saliva Analysis
A flow-through spectrophotometric bulk optode for the flow-injection determination of thiocyanate is described. As active constituents, the optode incorporates the lipophilized pH indicator 5-octadecanoyloxy-2-(4-nitrophenylazo)phenol and methyltridodecyl ammonium chloride, dissolved in a plasticized poly(vinyl)chloride membrane entrapped in a cellulose support. The optode is applied, in conjun...
متن کاملComparison of new optical sensor based on triazene ligand immobilized on PVC and triacetylcellulose membranes for Hg (II) Ion
For spectrophotometric analysis of Hg (II) ions, we have used and compared two membranes preparation methods using different polymer; one is poly(vinyl chloride) (PVC) and the other is triacetylcellulose (TAC). In the case of TAC membrane, it was treated with a ligand solution (1.166 × 10-3 mole L-1) in ethylenediamine at the ambient temperature for almost 2-5 min. However, in the case of PVC m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 25 7 شماره
صفحات -
تاریخ انتشار 2009