Determination of amino acids by capillary electrophoresis with differential resonant contactless conductivity detector.

نویسندگان

  • Dazhong Shen
  • Yaolong Li
  • Zhenli Zhang
  • Ping Zhang
  • Qi Kang
چکیده

The impedance of a capacitively coupled contactless conductivity detector (C(4)D) in capillary electrophoresis (CE) was measured by an impedance analysis method. The influence of solution conductivity and capillary dimension on impedance parameters was investigated. Under the experimental conditions used, 86-99.9% of the total impedance of a C(4)D is composed by its imaginary part from the capillary wall capacitor. With increasing inner diameter of capillary and solution conductivity in detection zone, the wall capacitance increases, which results in the increase in the response signal of C(4)D. But the wall capacitance is only 0.5-12% of the predicted value according to a cylinder capacitor model. As the change in solution resistance is detected in a resonant C(4)D (RC(4)D), the sensitivity of contactless conductivity detection in CE is improved. The application of an end-to-end differential RC(4)D (DRC(4)D) system in CE was demonstrated in the determination of 10 amino acids. The running buffer consisted of 2M acetic acid and 0.1% hydroxyethylcellulose (pH 2.1). The limit of detection for amino acids is in the range of 0.1-0.4 μM. Under our experimental conditions, the sensitivity of DRC(4)D enhances by a factor of 15-29 as compared with C(4)D.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous light emitting diode-induced fluorescence and contactless conductivity detection for capillary electrophoresis.

A combined detection system of simultaneous contactless conductometric and fluorescent detection for capillary electrophoresis (CE) has been designed and evaluated. The two processes share a common detection cell. A blue light-emitting diode (LED) was used as the excitation source and an optical fiber was used to collect the emitting fluorescence for fluorescent detection (FD). Inorganic ions, ...

متن کامل

Determination of haloacetic acids in water using solid-phase extraction/microchip capillary electrophoresis with capacitively coupled contactless conductivity detection.

Haloacetic acids (HAAs) were determined by a fast and simple analysis method based on microchip electrophoresis and capacitively coupled contactless conductivity detection (C(4)D). Two chlorinated acetic acids, dichloroacetic acid (DCAA) and TCA were detected in swimming pool water. Different BGEs were tested, and sodium carbonate was selected as BGE for the separation and detection in the repo...

متن کامل

Contactless Conductivity Detection in Ceramic Technology for On-Chip Electrophoresis

A capacitively coupled contactless conductivity detector produced in Low Temperature Co-fired Ceramic (LTCC) technology for microchip capillary electrophoresis (CE) is reported in this work. Electrodes located outside the measurement channel are used to sense impedance variations caused by conductive ions. The application of LTCC in combination with contactless conductivity detection is very pr...

متن کامل

Contactless conductivity detector for microchip capillary electrophoresis.

A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation chann...

متن کامل

On-chip contactless four-electrode conductivity detection for capillary electrophoresis devices.

In this contribution, a capillary electrophoresis microdevice with an integrated on-chip contactless four-electrode conductivity detector is presented. A 6-cm-long, 70-microm-wide, and 20-microm-deep channel was etched in a glass substrate that was bonded to a second glass substrate in order to form a sealed channel. Four contactless electrodes (metal electrodes covered by 30-nm silicon carbide...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 104  شماره 

صفحات  -

تاریخ انتشار 2013