Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review

نویسندگان

  • Greg Irving
  • John Holden
  • Richard Stevens
  • Richard J McManus
چکیده

OBJECTIVE To determine the diagnostic accuracy of different methods of blood pressure (BP) measurement compared with reference standards for the diagnosis of hypertension in patients with obesity with a large arm circumference. DESIGN Systematic review with meta-analysis with hierarchical summary receiver operating characteristic models. Bland-Altman analyses where individual patient data were available. Methodological quality appraised using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS2) criteria. DATA SOURCES MEDLINE, EMBASE, Cochrane, DARE, Medion and Trip databases were searched. ELIGIBILITY CRITERIA Cross-sectional, randomised and cohort studies of diagnostic test accuracy that compared any non-invasive BP tests (upper arm, forearm, wrist, finger) with an appropriate reference standard (invasive BP, correctly fitting upper arm cuff, ambulatory BP monitoring) in primary care were included. RESULTS 4037 potentially relevant papers were identified. 20 studies involving 26 different comparisons met the inclusion criteria. Individual patient data were available from 4 studies. No studies satisfied all QUADAS2 criteria. Compared with the reference test of invasive BP, a correctly fitting upper arm BP cuff had a sensitivity of 0.87 (0.79 to 0.93) and a specificity of 0.85 (0.64 to 0.95); insufficient evidence was available for other comparisons to invasive BP. Compared with the reference test of a correctly fitting upper arm cuff, BP measurement at the wrist had a sensitivity of 0.92 (0.64 to 0.99) and a specificity of 0.92 (0.85 to 0.87). Measurement with an incorrectly fitting standard cuff had a sensitivity of 0.73 (0.67 to 0.78) and a specificity of 0.76 (0.69 to 0.82). Measurement at the forearm had a sensitivity of 0.84 (0.71 to 0.92) and a specificity 0.75 of (0.66 to 0.83). Bland-Altman analysis of individual patient data from 3 studies comparing wrist and upper arm BP showed a mean difference of 0.46 mm Hg for systolic BP measurement and 2.2 mm Hg for diastolic BP measurement. CONCLUSIONS BP measurement with a correctly fitting upper arm cuff is sufficiently sensitive and specific to diagnose hypertension in patients with obesity with a large upper arm circumference. If a correctly fitting upper arm cuff cannot be applied, an incorrectly fitting standard size cuff should not be used and BP measurement at the wrist should be considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of Obesity and Hypertension in Isfahani Students Using Artificial Neural Network

Introduction: Obesity and hypertension are community health problems. The objective of this study was to diagnose obesity and hypertension in Isfahani students by artificial neural network. Method: The present study was a diagnostic and predictive one that used the information of 460 students aged 7-18 years old in Isfahan to design a neural network with 11 input variables (age, sex, weight, he...

متن کامل

Diagnosis of Obesity and Hypertension in Isfahani Students Using Artificial Neural Network

Introduction: Obesity and hypertension are community health problems. The objective of this study was to diagnose obesity and hypertension in Isfahani students by artificial neural network. Method: The present study was a diagnostic and predictive one that used the information of 460 students aged 7-18 years old in Isfahan to design a neural network with 11 input variables (age, sex, weight, he...

متن کامل

Resistant hypertension, case based approach to diagnosis and management: case report

Background: Resistant hypertension is defined when the blood pressure remains elevated above the therapeutic target levels despite the use of three antihypertensive agents including calcium channel blocker (CCB), renin-angiotensin system (RAS) blocker and a diuretic. These drugs should be used at maximally tolerated doses and white coat effect and non-adherence should also be excluded. In this ...

متن کامل

تخمین بدون کاف فشارخون مبتنی بر ویژگی‌های زمانی سیگنال نبض

Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...

متن کامل

Indirect MRA has More Diagnostic Value than Conventional MRI in Partial and Subscapularis Tears of Rotator Cuff

Background and purpose: Determining the severity and site of rotator cuff tear (RCT) is very important for choosing a treatment method. In this study, the diagnostic value of indirect magnetic resonance arthrography (I-MRA) and magnetic resonance imaging (MRI) were compared. Materials and methods: This cross-sectional study was performed in 36 patients attending an orthopedic clinic in 2020. P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016