A Rodent Model of Dynamic Facial Reanimation Using Functional Electrical Stimulation

نویسندگان

  • Mark A. Attiah
  • Julius de Vries
  • Andrew G. Richardson
  • Timothy H. Lucas
چکیده

Facial paralysis can be a devastating condition, causing disfiguring facial droop, slurred speech, eye dryness, scarring and blindness. This study investigated the utility of closed-loop functional electric stimulation (FES) for reanimating paralyzed facial muscles in a quantitative rodent model. The right buccal and marginal mandibular branches of the rat facial nerve were transected for selective, unilateral paralysis of whisker muscles. Microwire electrodes were implanted bilaterally into the facial musculature for FES and electromyographic (EMG) recording. With the rats awake and head-fixed, whisker trajectories were tracked bilaterally with optical micrometers. First, the relationship between EMG and volitional whisker movement was quantified on the intact side of the face. Second, the effect of FES on whisker trajectories was quantified on the paralyzed side. Third, closed-loop experiments were performed in which the EMG signal on the intact side triggered FES on the paralyzed side to restore symmetric whisking. The results demonstrate a novel in vivo platform for developing control strategies for neuromuscular facial prostheses.

منابع مشابه

Facial Rehabilitation

Facial nerve palsy (FNP) changes facial expression and leads to functional problems in facial movement and negative psychological effect on patients. Fortunately, some of FNP problems recover completely, but some others remain with some sequelae like asymmetry, muscle contracture, synkinesis, and hyperkinesias that need rehabilitation. This article aimed to investigate physiotherapy modalit...

متن کامل

In vivo excursion of the temporalis muscle-tendon unit using electrical stimulation: application in the design of smile restoration surgery following facial paralysis.

IMPORTANCE The temporalis muscle has the potential to substitute for the function of paralyzed facial muscles in a single-stage procedure when transferred as a muscle-tendon unit (MTU). OBJECTIVE To measure the available excursion of the temporalis MTU after release from the coronoid. DESIGN, SETTING, AND PARTICIPANTS Thirteen consecutive patients undergoing the temporalis MTU transfer proced...

متن کامل

Potential of an electric prosthesis for dynamic facial reanimation.

Chronic facial paralysis is a devastating condition with severe functional and emotional consequences. The current surgical armamentarium permits the predictable reestablishment of a protective blink as well as good resting symmetry. Yet the ultimate goal of symmetric, spontaneous emotional expression remains elusive despite significant progress in the areas of peripheral nerve grafting and fre...

متن کامل

Human Gait Control Using Functional Electrical Stimulation Based on Controlling the Shank Dynamics

Introduction: Efficient gait control using Functional Electrical Stimulation (FES) is an open research problem. In this research, a new intermittent controller has been designed to control the human shank movement dynamics during gait. Methods: In this approach, first, the three-dimensional phase space was constructed using the human shank movement data recorded from the healthy subjects. Then...

متن کامل

Principles and biomechanics of muscle tendon unit transfer: application in temporalis muscle tendon transposition for smile improvement in facial paralysis.

Muscle tendon unit (MTU) transfer is a common procedure performed to restore hand function after peripheral nerve or spinal cord injury. The principles of MTU transfer established for hand surgery can be adopted to optimize the dynamic excursion of the temporalis tendon transfer procedure for facial reanimation. Additionally, the force generating ability of a transferred MTU depends on the idea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017