[Purpose] The purpose of this research was to verify the reliability and validity of measuring respiration movement using a wearable strain sensor (WSS) which has been developed newly for clinical objective assessment. [Subjects and Methods] The 21 healthy male students were advised to conduct a breathing movement using measuring tape (MT) and WSS respectively, which was the measured at four locations on chest and abdomen wall. The different degree of chest expansion from maximal end of expiration to maximal end of inspiration was confirmed at each location. The intra-rater ICC (1,1) with 95% confidence interval was used to assess the test-retest reliability, Pearson's correlation analysis was performed to establish the validity. [Results] All ICC values for intra-rater reliability were from 0.94 to 0.98 at all locations, which means that there is a high correlation. All values for validity showed significantly positive, indicating that there is a correlation between the measuring tape and WSS at four locations. [Conclusion] Compared to the measuring tape, WSS has been proved to have high reliability and validity. The finding of this research indicated that WSS is reliable to use for objective measurement of respiratory movements on the chest and abdomen wall in clinical assessment.
منابع مشابه
Reliability of Measuring Lumbar Lordosis, Flexion and Extension Using Dual Inclinometer in Healthy Subjects and Patients with Non-Specific Chronic Low Back Pain
Objective: Accurate assessment of lumbar range of motion is of great value for both evaluating lumbar functions and monitoring treatment progress. Recent research indicates that there is no general consensus on the most valid and reliable method of measuring spinal range of motion. The purpose of this study was to determine the intra-rater reliability of lumbar flexion and extension measurement...
متن کاملThe Reliability and Concurrent Validity of Digital Inclinometer, Smartphone Applications, and the Cervical Range of Motion Device for Measuring the Cervical Range of Motion
Objectives: Changes in the Range of Motion (ROM) are essential criteria in determining the severity of spinal disorders and could be effective in predicting pain progression. Instruments to measure the ROM are costly and unavailable in most therapy settings. While there is a tendency in therapists to use their smartphones instead, there is no report to measure the suitability of smartphones to ...
متن کاملValidity and repeatability of inertial measurement units for measuring gait parameters.
Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this s...
متن کاملNanocomposite Fabric Sensors for Human Performance and Health Monitoring
Flexible and wearable sensors for human performance sensing have received increased attention, particularly for fitness, healthcare, sports, and military applications. In particular, the measurement of human vital signals provides rich datasets for assessing the subject’s physiological or psychological condition, which are directly linked to performance. Instead of using conventional, bulky, we...
متن کاملDesign, Modeling, and Construction of a New Tactile Sensor for Measuring Contact-Force
This paper presents the design, modeling, and testing of a flexible tactile sensor and its applications. This sensor is made of polymer materials and can detect the 2D surface texture image and contact-force estimation. The sensing mechanism is based on the novel contact deflection effect of a membrane. We measure the deflection of the membrane with measuring the strain in the membrane with emb...