[O] [H] functionalization on carbon nanotube using (O2–H2) gas mixture DC glow discharge

نویسندگان

  • Tamil Many K. Thandavan
  • Chiow San Wong
  • Siti Meriam Abdul Gani
  • Roslan Md Nor
چکیده

The [O] [H] functionalization of carbon nanotube (CNT) was studied using oxygen–hydrogen (O2–H2) gas mixture direct current (DC) glow discharge plasma technique for cathode/CNT-anode separation of 0.10 ± 0.01 cm. O2 and H2 were fixed at flowrate of 10.0 ml/min in order to obtain gas mixture ratio of 1:1. During the (O2–H2) gas mixture DC glow discharge, current–voltage (I–V) characteristic of gaseous species studied for various settings of gas pressures 1, 2, 3 and 4 mbar. The voltage at gap between cathode/CNT and anode, a breakdown voltage, was identified as ‘‘functionalization voltage’’ (Vfunc). Vfunc was noticed responsible for functionalization of functional groups on sidewall of CNT. The Vfunc were recorded as 796, 707, 594, and 663 V for gas pressures of 1, 2, 3 and 4 mbar, respectively. The co-relation between Vfunc and gas pressure was identified as linear relationship. But a voltage obtained due to the CNT/Cathode fall shows exponential relationship with the gas pressures. The possibility of [O] [H] functionalization was proved using Fourier transmission infra-red (FTIR) spectroscopy. Hydroxyl (–OH), carboxyl (–COOH), and carbonyl (–C=O) functional groups were identical as identified in the FTIR spectra. The field emission scanning electron microscope images show significant changes in the morphology of CNT which proves that the DC gas discharge plasma is a possible technique for [O] [H] functionalization on the sidewall of CNT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DFT Investigations for sensing capability of a single-walled Carbon nanotube for adsorptions H2, N2, O2 and CO molecules

Single-walled carbon nanotubes (SWCNTs) have a great deal of attention due to their unique properties. These properties of SWCNTs can be used in various devices such as nanosensors. SWCNTs nanosensors have fast response time and high sensitivity to special gas molecules which is very favorable for important applications. Recently, gas adsorption over outer surface of SWCNTs nanosensors was argu...

متن کامل

DFT Investigations for sensing capability of a single-walled Carbon nanotube for adsorptions H2, N2, O2 and CO molecules

Single-walled carbon nanotubes (SWCNTs) have a great deal of attention due to their unique properties. These properties of SWCNTs can be used in various devices such as nanosensors. SWCNTs nanosensors have fast response time and high sensitivity to special gas molecules which is very favorable for important applications. Recently, gas adsorption over outer surface of SWCNTs nanosensors was argu...

متن کامل

Chemistry in glow discharges of H2 / O2 mixtures. Diagnostics and modelling.

The chemistry of low pressure H2 + O2 discharges with different mixture ratios has been studied in a hollow cathode DC reactor. Neutral and positive ion distributions have been measured by mass spectrometry, and Langmuir probes have been used to provide charge densities and electron temperatures. A simple zero order kinetic model including neutral species and positive and negative ions, which t...

متن کامل

Surface chemistry improvement of carbon nanotube (CNT) supported Fischer–Tropsch nanocatalysts

Functionalization of carbon nanotube (CNT) was performed, during preparation of Fischer–Tropsch synthesis (FTS) via cobalt nanocatalysts, to modify the surface properties of CNT support. Common and functionalized CNT supported cobalt nanocatalysts were prepared using impregnation wetness method with cobalt loading of 15 wt.%. The catalysts were characterized by Brunauer–Emmett–Teller (BET), Fou...

متن کامل

A-C:H Film Removal in H2 and H2/N2O Glow and Afterglow Discharge

In the experiments a stream technique has been used and it has been shown that the main product of аC:H film gasification in an afterglow region of a direct current glow discharge was methane (hydrogen discharge). A hard а-C:H film erosion rate in the afterglow region decreased exponentially with distance from an atomic hydrogen source. The disadvantage of the hydrogen discharge is low erosion ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012