Evaluation of a minimally invasive glucose biosensor for continuous tissue monitoring

نویسندگان

  • Sanjiv Sharma
  • Zhenyi Huang
  • Michelle Rogers
  • Martyn Boutelle
  • Anthony E G Cass
چکیده

We describe here a minimally invasive glucose biosensor based on a microneedle array electrode fabricated from an epoxy-based negative photoresist (SU8 50) and designed for continuous measurement in the dermal compartment with minimal pain. These minimally invasive, continuous monitoring sensor devices (MICoMS) were produced by casting the structures in SU8 50, crosslinking and then metallising them with platinum or silver to obtain the working and reference electrodes, respectively. The metallised microneedle array electrodes were subsequently functionalised by entrapping glucose oxidase in electropolymerised polyphenol (PP) film. Sensor performance in vitro showed that glucose concentrations down to 0.5 mM could be measured with a response times (T90) of 15 s. The effect of sterilisation by Co60 irradiation was evaluated. In preparation for further clinical studies, these sensors were tested in vivo in a healthy volunteer for a period of 3-6 h. The sensor currents were compared against point measurements obtained with a commercial capillary blood glucometer. The epoxy MICoMS devices showed currents values that could be correlated with these. Graphical Abstract Microneedle arrays for continuous glucose monitoring in dermal interstitial fluid.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimally invasive enzyme microprobes: an alternative approach for continuous glucose monitoring.

Corresponding Author: Anthony Cass, D.Phil., FRSC, Institute of Biomedical Engineering, Department of Chemistry, Imperial College London, South Kensington Campus, Exhibition Road, London SW7 2AZ; email address [email protected] Continuous glucose monitoring has been shown to improve glycemia in diabetes.1,2 To minimize the pain, inconvenience, and discomfort associated with long-term implan...

متن کامل

Delays in minimally invasive continuous glucose monitoring devices: a review of current technology.

Through the use of enzymatic sensors-inserted subcutaneously in the abdomen or ex vivo by means of microdialysis fluid extraction-real-time minimally invasive continuous glucose monitoring (CGM) devices estimate blood glucose by measuring a patient's interstitial fluid (ISF) glucose concentration. Signals acquired from the interstitial space are subsequently calibrated with capillary blood gluc...

متن کامل

Non-invasive Optical Techniques for determination of blood Glucose levels: A Review Article

This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...

متن کامل

Bilateral C5 Palsy Following a Circumferential Surgery for Cervical Spondylotic Myelopathy: Case Report and Review (In press)

Background and Importance: The development of C5 root palsy is a well-known potential complication of cervical spine surgeries for the correction of cervical spondylotic myelopathy. It typically occurs unilaterally but on extremely rare occasions it might occur as a bilateral anomaly. The value of intraoperative neurophysiologic monitoring in detection of iatrogenic acute versus delayed onset C...

متن کامل

Evaluation of the difference in surgical margin values in excisional skin lesions during surgery and after formalin fixation

Background: Surgical margin determination in malignant lesions is essential and has a direct impact on the choice of postoperative treatments and patient follow-up. Therefore, the processes affecting this variable are worth exploring. This study aimed to evaluate the difference in surgical margin values in excisional skin samples during surgery and after formalin fixation. Methods: A cross-sec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 408  شماره 

صفحات  -

تاریخ انتشار 2016