Comparison of decentration and tilt between one piece and three piece polymethyl methacrylate intraocular lenses.

نویسندگان

  • K Hayashi
  • H Hayashi
  • F Nakao
  • F Hayashi
چکیده

BACKGROUND The extent of the decentration and tilt was prospectively compared between one piece polymethyl methacrylate (PMMA) and three piece PMMA intraocular lenses (IOLs) which were implanted in the capsular bag after performing continuous curvilinear capsulorhexis. METHODS 91 patients underwent a one piece PMMA IOL implantation in one eye as well as the implantation of the three piece PMMA IOL with polyvinylidene fluoride loops in the opposite eye. The length of the lens decentration and the angle of the tilt were quantitated using the anterior eye segment analysis system (EAS-1000) at 1 week as well as 1, 3, and 6 months postoperatively. RESULTS The mean length of the decentration in the one piece IOL was smaller than that in the three piece IOL at 1 week (p = 0.0092), 1 month (p = 0.0044), 3 months (p = 0.0069), and 6 months (p = 0.0010) postoperatively. However, no significant difference was found in the degree of the tilt between the two types of IOLs throughout the observation periods. CONCLUSION These results clarified that the one piece PMMA IOL with rigid PMMA haptics implanted in the capsular bag provides a better centration than the three piece PMMA IOL with flexible haptics, whereas the tilt was the same between the two types of IOLs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses.

AIMS To compare the postoperative performance of single and three piece acrylic foldable intraocular lenses (IOLs). METHODS 20 patients underwent bilateral cataract surgery with a single piece SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes were randomly assigned to either a single or three piece lens. The amount of IOL decentration and tilt, area of anterior cap...

متن کامل

SCIENTIFIC REPORT A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses

Aims: To compare the postoperative performance of single and three piece acrylic foldable intraocular lenses (IOLs). Methods: 20 patients underwent bilateral cataract surgery with a single piece SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes were randomly assigned to either a single or three piece lens. The amount of IOL decentration and tilt, area of anterior cap...

متن کامل

Comparisons of the in-the-bag stabilities of single-piece and three-piece intraocular lenses for age-related cataract patients: a randomized controlled trial

BACKGROUND To compare the in-the-bag stability and visual function of single-piece intraocular lenses (IOLs) and three-piece IOLs. METHODS A total of 65 patients with age-related cataracts (80 eyes) were enrolled and randomly assigned to receive in-the-bag implantation of either a single-piece IOL (40 eyes) or a three-piece IOL (40 eyes). Follow-up visits were conducted at 1 week, 1 month and...

متن کامل

Impact of intraocular lens haptic design and orientation on decentration and tilt.

PURPOSE To assess the effect of intraocular lens (IOL) orientation (vertical versus horizontal) and haptic design (1-piece versus 3-piece) on centration and tilt using a Purkinje meter. SETTING Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom. DESIGN Randomized pilot study with intrapatient comparison. METHODS In part 1 of this study, patients received plate-haptic IOL...

متن کامل

The Balanced Two-String Technique for Sulcus Intraocular Lens Implantation in the Absence of Capsular Support

Purpose. To describe and explore an alternative approach for sulcus intraocular lens (IOL) implantation in the absence of capsular support. Methods. The commonly available one-piece poly(methyl methacrylate) (PMMA) lens is stabilized in the sulcus by two intraocular horizontal strings of 10/0 polypropylene suture passed through the lens dialing holes in opposite directions to achieve a mechanic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 82 4  شماره 

صفحات  -

تاریخ انتشار 1998