Optimizing the dialysate calcium concentration in bicarbonate haemodialysis.
نویسندگان
چکیده
BACKGROUND There is no consensus regarding the optimal dialysate calcium concentration (DCa) during haemodialysis (HD). Low DCa may predispose to acute arrhythmias, whereas high DCa increases the long-term risk of soft tissue calcifications. METHODS Twenty-two HD patients treated in four dialysis centres underwent two HD sessions, respectively, with 1.5 and 1.25 mmol/L total DCa. Calcium mass balance (CMB) was calculated from ionized calcium (iCa) in the dialysate and blood at the start and end of each run, using a kinetic formula to define the mean concentrations in the blood and dialysate and then estimating CMBs over the entire treatments. RESULTS Mean blood iCa levels increased using 1.5 DCa, whereas they remained unchanged using 1.25 DCa. Diffusive CMB positively correlated with the dialysate/blood iCa gradient. With 1.5 DCa, diffusive CMBs were strongly positive at the blood side and negative at the dialysate side, indicating transfer from dialysate to blood. With 1.25 DCa, despite a negative dialysate/blood iCa gradient, diffusive CMB was slightly positive in blood and negative in dialysate. The global balances based on both the convective and diffusive components showed a positive net transfer of Ca from dialysate to blood with 1.5 DCa and an approximately neutral Ca flux with 1.25 DCa. CONCLUSIONS While CMB is nearly neutral when using 1.25 DCa, the use of 1.5 DCa results in a gain of Ca during HD. The risks associated with Ca load should be considered in the choice of DCa prescription for HD but need also be weighed against the risk of worse haemodynamic dialysis tolerance.
منابع مشابه
Total dialysate calcium effects on calcium balance during dialysis.
INTRODUCTION Total dialysate calcium concentration has an important influence on calcium metabolism in bicarbonate high-flux dialysis. The aim of the study is to investigate the influence of different dialysate calcium concentrations on serum concentration of ionised calcium and on the balance of total dialysate calcium. MATERIALS AND METHODS A total of 20 stable aneuric patients on chronic b...
متن کاملCitrate- vs. acetate-based dialysate in bicarbonate haemodialysis: consequences on haemodynamics, coagulation, acid-base status, and electrolytes
BACKGROUND A concentrate for bicarbonate haemodialysis acidified with citrate instead of acetate has been marketed in recent years. The small amount of citrate used (one-fifth of the concentration adopted in regional anticoagulation) protects against intradialyser clotting while minimally affecting the calcium concentration. The aim of this study was to compare the impact of citrate- and acetat...
متن کاملOptimizing haemodialysate composition
Survival and quality of life of dialysis patients are strictly dependent on the quality of the haemodialysis (HD) treatment. In this respect, dialysate composition, including water purity, plays a crucial role. A major aim of HD is to normalize predialysis plasma electrolyte and mineral concentrations, while minimizing wide swings in the patient's intradialytic plasma concentrations. Adequate s...
متن کاملAutomated peritoneal dialysis with 'on-line'-prepared bicarbonate-buffered dialysate: technique and first clinical experiences.
BACKGROUND Automated peritoneal dialysis (APD) has the possibility of increasing the dialysis efficacy by using higher fill volumes, frequent dialysate exchanges, and tidal techniques. It is then possible to treat patients adequately without residual renal function. The drawbacks of the required high amounts of dialysis solution of up to 30 litres per session are the high costs of lactate-based...
متن کاملHaemodynamic consequences of changing bicarbonate and calcium concentrations in haemodialysis fluids
BACKGROUND In a previous study we demonstrated that mild metabolic alkalosis resulting from standard bicarbonate haemodialysis induces hypotension. In this study, we have further investigated the changes in systemic haemodynamics induced by bicarbonate and calcium, using non-invasive procedures. METHODS In a randomized controlled trial with a single-blind, crossover design, we sequentially ch...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 27 6 شماره
صفحات -
تاریخ انتشار 2012