The efficacy of local exhaust ventilation for controlling dust exposures during concrete surface grinding.

نویسندگان

  • Gerry A Croteau
  • Mary Ellen Flanagan
  • Janice E Camp
  • Noah S Seixas
چکیده

This study assessed the effectiveness of a commercially available local exhaust ventilation (LEV) system for controlling respirable dust and crystalline silica exposures during concrete grinding activities. Surface grinding was conducted at six commercial building construction sites in Seattle, WA, by cement masons. Time-integrated filter samples and direct reading respirable dust concentrations were collected using a cyclone in line with a direct reading respirable dust monitor. Personal exposure levels were determined with and without LEV, one sample directly after the other. A total of 28 paired samples were collected in which three different dust collection shroud configurations were tested. Data obtained with a direct reading respirable dust monitor were adjusted to remove non-work task-associated dust exposures and was subsequently used to calculate the exposure reduction achieved. The application of LEV resulted in a reduction in the overall geometric mean respirable dust exposure from 4.5 to 0.14 mg/m(3), a mean exposure reduction of 92%. Despite the effective control of dust generated during surface grinding, 22 and 26% of the samples collected while LEV was being used were greater than the 8 h time-weighted average permissible exposure limit (Occupational Safety and Health Administration) and threshold limit value (American Congress of Governmental Industrial Hygienists) for respirable crystalline silica, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities.

This study assessed the effectiveness of commercially available local exhaust ventilation (LEV) systems for controlling respirable dust and crystalline silica exposures during concrete cutting and grinding activities. Work activities were performed by union-sponsored apprentices and included tuck-point grinding, surface grinding, paver block and brick cutting (masonry saw), and concrete block c...

متن کامل

Efficiency of a tool-mounted local exhaust ventilation system for controlling dust exposure during metal grinding operations.

In general, control of metal dust from hand-held disk grinders is difficult because such respirable dust tends to disperse in every direction around the grinding wheel and cannot be captured effectively by a conventional exhaust hood. The author described the application of a custom-made tool-mounted local exhaust ventilation (LEV) system attached to a hand-held disk grinder, and by laboratory ...

متن کامل

Respirable crystalline silica dust exposure during concrete finishing (grinding) using hand-held grinders in the construction industry.

Studies reporting the findings of exposure to crystalline silica dust during concrete finishing in construction settings are scarce due to the dynamic nature of the activity and the existence of many confounding factors. This study was initiated to explore the issue. A total of 49 personal respirable dust samples were collected during concrete finishing while workers used hand-held grinders. On...

متن کامل

Silica dust exposures during selected construction activities.

This study characterized exposure for dust-producing construction tasks. Eight common construction tasks were evaluated for quartz and respirable dust exposure by collecting 113 personal task period samples for cleanup; demolition with handheld tools; concrete cutting; concrete mixing; tuck-point grinding; surface grinding; sacking and patching concrete; and concrete floor sanding using both ti...

متن کامل

Dust emission and efficiency of local exhaust ventilation during cast iron grinding.

A method of determining dust emission and efficiency of its removal by means of local exhaust ventilation from machinery has been described. It complies with Standard No. EN 1093-3:1996 (European Committee for Standardization, 1996) and consists in determining air pollution concentrations in the measurement duct used for air removal from the chamber incorporating devices to be tested. The air v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 48 6  شماره 

صفحات  -

تاریخ انتشار 2004