Clear corneal incision of 2.75 mm for cataract surgery induces little change of astigmatism in eyes with low preoperative corneal cylinder.

نویسندگان

  • F Giansanti
  • E Rapizzi
  • G Virgili
  • R Mencucci
  • A Bini
  • L Vannozzi
  • U Menchini
چکیده

PURPOSE To assess the early astigmatic effect induced by 2.75 mm clear cornea incisions with different locations for cataract surgery. METHODS A total of 146 eyes of different patients were studied prospectively. Cataract surgery was performed by three surgeons, two using a temporal approach and one using a superior approach. For both approaches, the site of the 2.75 mm incision was allowed to vary slightly according to the characteristics of the eye and orbit. Computerized videokeratography was used to measure corneal astigmatism before surgery and after 1, 4, and 12 weeks. Corneal astigmatism was recorded as cylinder and axis and it was then converted to 2 power vector. Model based prediction and comparisons were made for the most commonly used corneal incision sites: 12 (both eyes), 2 (left eye), and 8 (right eye) o'clock meridian. RESULTS After 3 months the differences in corneal astigmatism (JCC 0 ) between the incisions performed at 12 and 2 o'clock were not statistically significant (-0.08, 95% CI: -0.19, -0.02); the differences in JCC 0 between incisions at 12 and 8 o'clock were -0.17 (95% CI: -0.30, -0.05; p<0.01). After 3 months the change in JCC 0 for the patients with 0.5 D with-the-rule preoperatively were -0.32 (95% CI: -0.44, 0.21; p<0.01) for incisions at 12; -0.24 (95% CI: -0.36, 0.13; p<0.01) for incisions at 2; and -0.15 (95% CI: -0.27, -0.03; p<0.05) for incisions at 8. After 3 months the changes of JCC 0 for the patients with -0.5 D against-the-rule pre-operatively were 0.10 (95% CI: 0.04, 0.23) for incision at 12; 0.18 (95% CI: 0.04, 0.32; p<0.05) for incisions at 2; and 0.27 (95% CI: 0.14, 0.40; p<0.01) for incisions at 8 o'clock. The oblique astigmatic vector (JCC 45 ) was very modest in this sample before surgery and underwent minimal and nonsignificant change after it. CONCLUSIONS This study has shown that a 2.75 mm clear corneal incision causes a small change of corneal cylinder regardless of incision site.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimizing Surgically Induced Astigmatism at the Time of Cataract Surgery Using a Square Posterior Limbal Incision

Purpose. To compare the surgically induced astigmatism from clear corneal and square posterior limbal incisions at the time of cataract surgery. Methods. Surgically induced astigmatism was calculated for a set of eyes after cataract surgery using a temporal 2.2 mm square posterior limbal incision. Results were compared to similar available data from surgeons using clear corneal incisions of sim...

متن کامل

Comparison of Surgically-induced Astigmatism after Combined Phacoemulsification and 23-Gauge Vitrectomy: 2.2-mm vs. 2.75-mm Cataract Surgery

PURPOSE The 2.2-mm microincision cataract surgery and small-gauge vitrectomy system is known to result in less surgically-induced astigmatism (SIA) in comparison to conventional surgical methods. We compared the amounts of SIA after combined phacoemulsification and 23-gauge transconjunctival sutureless vitrectomy (23G-TSV) using the 2.2-mm microincision and 2.75-mm standard incision methods. ...

متن کامل

The role of sideport incision in astigmatism change after cataract surgery

PURPOSE To study the changes in corneal astigmatism after cataract surgery when the sideport incision is performed at a predetermined location away from the tunnel incision. SETTING General Hospital of Piraeus "Tzaneio", Attiki, Greece. MATERIALS AND METHODS A total of 333 eyes with corneal astigmatism ≤1.5 diopters (D) underwent cataract surgery. A three-step superotemporal clear corneal i...

متن کامل

Torsional and flattening effect on corneal astigmatism after cataract surgery: a retrospective analysis

BACKGROUND To evaluate the torsional and flattening effect of steep meridian incisions and influence of posterior corneal astigmatism (PCA) on total corneal astigmatism (TCA) after cataract surgery. METHODS One hundred thirty-two eyes underwent cataract surgery with steep meridian 2.2 mm microcoaxial and 2.85 mm conventional clear corneal incisions. Eyes were divided into with-the-rule (WTR) ...

متن کامل

Astigmatism in cataract surgery MAURICE

We report on our investigation into astigmatism in 40 eyes following a corneal cataract incision closed with a continuous 10/0 nylon monofilament suture (Ethilon). Immediately after surgery there was astigmatism caused by the nylon suture (suture-induced astigmatism), its severity depending on the tightness of the suture. It ranged from 1 to 10 5 dioptres, the mean value 4 09 dioptres with a st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of ophthalmology

دوره 16 3  شماره 

صفحات  -

تاریخ انتشار 2006