Comparison of anti-scatter grids for digital imaging with use of a direct-conversion flat-panel detector.
نویسندگان
چکیده
Our purpose in this study was to establish a selection standard for anti-scatter grids for a direct conversion flat-panel detector (FPD) system. As indices for grid evaluation, we calculated the selectivity, Bucky factor, and the signal-to-noise ratio improvement factor (SIF) by measuring rates of scatter transmission, primary transmission, and total transmission (based on the digitally displayed measurement values of the FPD system), using 4 acrylic phantoms of different thicknesses. The results showed that the SIF was less than 1.0 when the phantom thickness was 5 cm. When the phantom thickness was 25 cm and the grid ratio was 16:1, the SIF was 1.505 and 1.518 (maximum value) at 90 and 120 kV, respectively. Compared with the grid ratio of 12:1, the SIF at the grid ratio 16:1 was improved by 6.1% at 90 kV, and by 7.0% at 120 kV. In a direct-conversion FPD system, the grid ratio of 16:1 is considered adequate for eliminating the scattered-radiation effect when much scattered radiation is present, such as with a thick imaged object or a high X-ray tube voltage.
منابع مشابه
The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography.
Dynamic, flat-panel, solid-state, x-ray image detectors for use in digital fluoroscopy and fluorography emerged at the turn of the millennium. This new generation of dynamic detectors utilize a thin layer of x-ray absorptive material superimposed upon an electronic active matrix array fabricated in a film of hydrogenated amorphous silicon (a-Si:H). Dynamic solid-state detectors come in two basi...
متن کامل[A new method for eliminating scatter components from a digital X-ray image by later processing].
The anti-scatter grid is generally used as a way of eliminating scattered radiation from X-ray photographs. This does not change even if the detector system changes from an analogue system to a digital system such as the flat-panel detector. We developed a new method that uses software to eliminate scatter components from digital X-ray images taken without the use of an anti-scatter grid. With ...
متن کاملDirect-conversion flat-panel X-ray image detectors
Flat-panel X-ray image detectors have been shown to be suitable to replace the conventional X-ray filmjscreen cassettes for medical radiography (static or snapshot imaging). They are capable of capturing the X-ray image digitally immediately after the X-ray exposure which permits a convenient clinical transition to digital radiography. There are two general approaches to the flat-panel X-ray de...
متن کامل[Correlation between basic imaging properties and subjective evaluations of two digital radiographic X-ray systems based on direct-conversion flat panel detector].
The purpose of this study was to examine the correlation between the basic imaging properties of two digital radiographic X-ray systems with a direct conversion flat-panel detector and their image qualities, which were evaluated by the observer in hard copy and soft copy studies. The subjective image quality was evaluated and compared in terms of the low-contrast detectability and image sharpne...
متن کاملAnalytical Corrections for Beam-hardening and Object Scatter in Volumetric Computed Tomography Systems
The advent of the use of digital area detectors in Volumetric Computed Tomography (VCT) systems has brought with it the challenges of achieving image quality comparable to that provided by earlier planar industrial CT systems equipped with highly collimated and efficient linear detector arrays. Particularly for imaging with higher voltage x-ray sources up to 450kVp, among the most distinct imag...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiological physics and technology
دوره 5 1 شماره
صفحات -
تاریخ انتشار 2012