Analysis of the Operating Characteristics of a Low Evaporation Temperature R404A Refrigeration System
نویسندگان
چکیده
A refrigeration system which was originally designed using R502 as refrigerant was rebuilt to adapt the special requirements of R404A. The experiments, both for R502 and R404A, on this system were done and some parameters such as evaporating temperature, condensing temperature, discharge temperature, compressor input power and so on were measured under different working conditions. Then the operating characteristics and the performances were compared between R404A and R502. The influences of R404A as refrigerant on refrigeration system were further analyzed. Some recommendations for existing R502 refrigeration systems to use R404A as refrigerants were put forward in the end of this paper.
منابع مشابه
Numerical Simulation of R410a-R23 and R404A-R508B Cascade Refrigeration System
Capacity and efficiency of any refrigerating system diminish rapidly as the difference between the evaporating and condensing temperature is increased by a reduction in the evaporator temperature. The single stage vapour compression refrigeration system using various refrigerants are limited to an evaporator temperature of -40 0C. Below temperature of -40 0C the either cascade refrigeration sys...
متن کاملNumerical Simulation of Heat Exchanger Area of R410A-R23 and R404A-R508B Cascade Refrigeration System at Various Evaporating and Condensing Temperature
Capacity and efficiency of any refrigerating system diminish rapidly as the difference between the evaporating and condensing temperature is increased by reduction in the evaporator temperature. The single stage vapour compression refrigeration system is limited to an evaporator temperature of -40 C. Below temperature of -40 C the either cascade refrigeration system or multi stage vapour compre...
متن کاملMathematical Method and Thermodynamic Approaches to Design Multi-Component Refrigeration Used in Cryogenic Process Part I: Optimal Operating Conditions
Abstract: Minimizing the work consumed in refrigeration system is the most effective measure to reduce the cost of products in sub-ambient chemical processes. The introduction of mixed working fluids into refrigeration system in place of pure working fluids is a recent advancement applied in the field. Due to the lack of systematic design method for Mixed Refrigerant Cycle (MRC), conventional a...
متن کاملAdvanced Analysis of Dew Point Control Unit of Hybrid Refrigeration Systems in Gas Refineries
In this paper, an advanced analysis of a novel hybrid compression-absorption refrigeration system (HCARS) for natural gas dew point control unit in a gas refinery is presented. This unit separates the heavy hydrocarbon molecules in the natural gas, which is traditionally carried out by natural gas cooling in a compression refrigeration cycle (CRS). The power input required for the refrigeration...
متن کاملPerformance Evaluation and Optimal Design of Supermarket Refrigeration Systems with Supermarket Model “SuperSim”, Part II: Model Applications
As described in Part I, the supermarket simulation software “SuperSim” with its integrated refrigeration, building and HVAC system models, can be used to evaluate, compare and optimize alternative supermarket refrigeration systems. In Part II the model was used to evaluate and compare the performance of a CO2 booster refrigeration system with that of a conventional R404A multiplex system in a s...
متن کامل