An In Vitro Assessment of Gutta-Percha Coating of New Carrier-Based Root Canal Fillings
نویسندگان
چکیده
The first aim of this paper was to evaluate the push-out bond strength of the gutta-percha coating of Thermafil and GuttaCore and compare it with that of gutta-percha used to coat an experimental hydroxyapatite/polyethylene (HA/PE) obturator. The second aim was to assess the thickness of gutta-percha around the carriers of GuttaCore and HA/PE obturators using microcomputed tomography ( μ CT). Ten (size 30) 1 mm thick samples of each group (Thermafil, GuttaCore, and HA/PE) were prepared. An orthodontic wire with a diameter of 0.5 mm was attached to the plunger of an Instron machine in order to allow the push-out testing of the gutta-percha coating. Five samples of (GuttaCore and HA/PE) were scanned using μ CT. The data obtained were analysed with one-way analysis of variance and Tukey post hoc test. HA/PE obturators exhibited significantly higher push-out bond strength (P < 0.001) determined at 6.84 ± 0.96 than those of Guttacore around 3.75 ± 0.75 and Thermafil at 1.5 ± 0.63. GuttaCore demonstrated significantly higher bond strength than Thermafil (P < 0.001). μ CT imaging revealed that the thickness of gutta-percha around the experimental HA/PE carrier was homogeneously distributed. The bondability and thickness of gutta-percha coating around HA/PE carriers were superior to those of GuttaCore and Thermafil obturators.
منابع مشابه
A l2-month longitudinal in vitro leakage study on a new silicon-based root canal filling material (Gutta-Flow).
OBJECTIVE This study was performed to determine in vitro the short- and long-term sealing ability of a recently developed silicon-based root canal filling material (Gutta-Flow). STUDY DESIGN Sixty human upper central incisors were divided into 3 groups (n = 20). The root canals were instrumented and obturated with laterally compacted gutta-percha and AH26 sealer (group 1), continuous-wave the...
متن کاملEffects of dentin bonding agents (DBA) coronal leakage in root canal therapy (In – Vitro)
Effects of dentin bonding agents (DBA) coronal leakage in root canal therapy (In – Vitro) Dr. MR. Sharifian* - Dr. E. Kazemifar** *- Assistant Professor of Endodontics Dept. - Faculty of Dentistry – Tehran University of Medical Sciences. **- Dentist. Background and Aim: Coronal sealing plays an important role in the prevention of root canal system reinfection and the access of irritants to peri...
متن کاملComparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha
Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...
متن کاملFP core carrier technique: thermoplasticized gutta-percha root canal obturation technique using polypropylene core.
Core carrier techniques are unique among the various root canal filling techniques for delivering and compacting gutta-percha in the prepared root canal system. Thermafil (TF), considered the major core carrier device, is provided as an obturator consisting of a master core coated with thermoplasticized gutta-percha. We have devised a thermoplasticized gutta-percha filling technique using a pol...
متن کاملIn Vitro Effects of External Pressure Changes on the Sealing Ability under Simulated Diving Conditions
Aim. To measure and validate the permeability of pressure changes in correlation to different root filling techniques. Methods. Eighty extracted single-rooted teeth were randomly assigned to one of eight groups of ten teeth. Following standardized instrumentation and irrigation, root canal fillings were performed using either cold lateral condensation, a warm carrier-based gutta-percha obturati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2014 شماره
صفحات -
تاریخ انتشار 2014