Flow-induced platelet activation in mechanical heart valves.
نویسندگان
چکیده
BACKGROUND AND AIM OF THE STUDY A study was conducted to measure in vitro the procoagulant properties of platelets induced by flow through mechanical heart valves. METHODS The procoagulant activity of platelets was measured using a real-time assay of platelet activation state (PAS), which was based on a modification of the prothrombinase method. Acetylated prothrombin was used instead of normal prothrombin in this assay in order to eliminate the positive feedback effect of thrombin. This enabled a direct comparison between thrombin generation rates in the assay and the flow stresses that induce platelet activation. Gel-filtered platelets (10(5) per microliters) were circulated through a left ventricular assist device with two Björk-Shiley mono-leaflet mechanical heart valves mounted in opposition, and platelet activation state was measured over 30-min time courses. The results were compared with two configurations in which the leaflet motion of one of the valves was restricted (severely restricted and mildly restricted), mimicking defective function of a compromised valve in vivo, and with a control lacking valves. RESULTS The severely restricted valve activated the platelets at a rate eight-fold higher than with unrestricted valves, and three-fold higher than with mildly restricted valves. Both restricted valves activated platelets at rates significantly higher than either the control (no valves) or the unrestricted valve. CONCLUSION Flow through compromised mechanical heart valves causes platelet activation, which can be measured with a modified prothrombinase assay system. The ability to perform sensitive quantitative measurements in cardiovascular devices in vitro may have a significant impact on the design and development of these devices.
منابع مشابه
Flow Induced Platelet Activation in Mechanical Heart Valves -- in vitro Studies in a LVAD
Thromboembolism is a common complication of mechanical heart valves (MHV). The objective of this study was to elucidate mechanisms of thromboembolism in flow past MHV in vitro. Gel-filtered platelets were recirculated in a buffer through MHV mounted in a model of a left ventricular assist device (LVAD), and their activation measured by an innovative platelet activity state (PAS) assay. In a fir...
متن کاملFlow-induced platelet activation in a St. Jude mechanical heart valve, a trileaflet polymeric heart valve, and a St. Jude tissue valve.
Polymer heart valves have been under investigation since the 1960s, but their success has been hampered by an overall lack of durability mainly due to calcification of the leaflets and a relatively high rate of thromboembolic complications. A new polymer (Quatromer) trileaflet design was tested for its thrombogenic potential and was compared to that of existing prosthetic heart valves routinely...
متن کاملFlow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies.
A model for platelet activation based on the theory of damage, incorporating cumulative effects of stress history and past damage (senescence) was applied to a three-dimensional (3-D) model of blood flow through a St. Jude Medical (SJM) bileaflet mechanical heart valve (MHV), simulating flow conditions after implantation. The calculations used unsteady Reynolds-averaged Navier-Stokes formulatio...
متن کاملDevice Thrombogenicity Emulator (DTE)--design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs.
Patients who receive prosthetic heart valve (PHV) implants require mandatory anticoagulation medication after implantation due to the thrombogenic potential of the valve. Optimization of PHV designs may facilitate reduction of flow-induced thrombogenicity and reduce or eliminate the need for post-implant anticoagulants. We present a methodology entitled Device Thrombogenicty Emulator (DTE) for ...
متن کاملComparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.
The hemodynamic and the thrombogenic performance of two commercially available bileaflet mechanical heart valves (MHVs)--the ATS Open Pivot Valve (ATS) and the St. Jude Regent Valve (SJM), was compared using a state of the art computational fluid dynamics-fluid structure interaction (CFD-FSI) methodology. A transient simulation of the ATS and SJM valves was conducted in a three-dimensional mode...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of heart valve disease
دوره 13 3 شماره
صفحات -
تاریخ انتشار 2004