A dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac‐based systems

نویسندگان

  • Chuxiong Ding
  • Cheng‐Hui Chang
  • Joshua Haslam
  • Robert Timmerman
  • Timothy Solberg
چکیده

The aim of this study is to compare the dosimetric characteristics of robotic and conventional linac-based SBRT techniques for lung cancer, and to provide planning guidance for each modality. Eight patients who received linac-based SBRT were retrospectively included in this study. A dose of 60 Gy given in three fractions was prescribed to each target. The Synchrony Respiratory Tracking System and a 4D dose calculation methodology were used for CyberKnife and linac-based SBRT, respectively, to minimize respiratory impact on dose calculation. Identical image and contour sets were used for both modalities. While both modalities can provide satisfactory target dose coverage, the dose to GTV was more heterogeneous for CyberKnife than for linac planning/delivery in all cases. The dose to 1000 cc lung was well below institutional constraints for both modalities. In the high dose region, the lung dose depended on tumor size, and was similar between both modalities. In the low dose region, however, the quality of CyberKnife plans was dependent on tumor location. With anteriorly-located tumors, the CyberKnife may deliver less dose to normal lung than linac techniques. Conversely, for posteriorly-located tumors, CyberKnife delivery may result in higher doses to normal lung. In all cases studied, more monitor units were required for CyberKnife delivery for given prescription. Both conventional linacs and CyberKnife provide acceptable target dose coverage while sparing normal tissues. The results of this study provide a general guideline for patient and treatment modality selection based on dosimetric, tumor and normal tissue sparing considerations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The colossal circumvention of the lung lesion during lung stereotaxy

This is a case report on stereotaxic (Stereotactic Body Radiotherapy-SBRT) for lung cancer located in the left lower lobe (Segment 6, S6). There have been no reports on marked displacement of the peripheral lung cancer during radiotherapy. A pulmonary nodule was discovered on computed tomography (CT) conducted for a persistent cough in an 87-year-old male. According to diagnostic imaging, this ...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Dosimetric Comparison of Real-Time MRI-Guided Tri-Cobalt-60 Versus Linear Accelerator-Based Stereotactic Body Radiation Therapy Lung Cancer Plans

PURPOSE Magnetic resonance imaging-guided radiation therapy has entered clinical practice at several major treatment centers. Treatment of early-stage non-small cell lung cancer with stereotactic body radiation therapy is one potential application of this modality, as some form of respiratory motion management is important to address. We hypothesize that magnetic resonance imaging-guided tri-co...

متن کامل

Flattening filter‐free linac improves treatment delivery efficiency in stereotactic body radiation therapy

Stereotactic body radiation therapy (SBRT) employs precision target tracking and image-guidance techniques to deliver ablative doses of radiation to localized malignancies; however, treatment with conventional photon beams requires lengthy treatment and immobilization times. The use of flattening filter-free (FFF) beams operating at higher dose rates can shorten beam-on time, and we hypothesize...

متن کامل

Investigation of lung normal tissue doses in lung tumors radiation therapy using both gated and conventional radiotherapy

Introduction: In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the clinical target volume (CTV). With the margin increasing, a larger volume of normal tissue will be exposed to high-dose.  In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010