Comparing OMI-TOMS and OMI-DOAS total ozone column data

نویسندگان

  • M. Kroon
  • J. P. Veefkind
  • M. Sneep
  • R. D. McPeters
  • P. K. Bhartia
  • P. F. Levelt
چکیده

[1] The Ozone Monitoring Instrument (OMI) project team uses two total ozone retrieval algorithms in order to maintain the long-term record established with Total Ozone Mapping Spectrometer (TOMS) data as well as to improve the ozone column estimate using the hyperspectral capability of OMI. The purpose of this study is to assess where the algorithms produce comparable results and where the differences are significant. Starting with the same set of Earth reflectance data, the total ozone data used in this study have been derived using OMI-TOMS and OMI–Differential Optical Absorption Spectroscopy (DOAS) algorithms. OMI-TOMS is based on the TOMS version 8 algorithm that has been used to process TOMS data taken since November 1978. The OMI-DOAS retrieval algorithm was developed specifically for OMI. It takes advantage of the hyperspectral feature of the OMI instrument to reduce errors due to aerosols, clouds, surface, and sulfur dioxide from volcanic eruptions. The OMI-DOAS algorithm also has improved correction for cloud height. The mean differences in the ozone column derived from the two algorithms vary from 0 to 9 DU (0–3%), and their correlation coefficients vary between 0.89 and 0.99 with latitude and season. The largest differences occur in the polar regions and over clouds. Some of the differences are due to stray light, dark current, and other instrumental errors that have been corrected in the new version of the OMI radiance/irradiance data set (collection 3). Other differences are algorithmic. OMI-DOAS algorithmic errors identified through this analysis are also being corrected in collection 3 reprocessing. However, for consistency with the long-term TOMS record, OMI-TOMS collection 3 data will still be based on the TOMS V8 algorithm. Preliminary analysis shows much better agreement in the two total ozone data sets after reprocessing. Reprocessed collection 3 data from both algorithms will be available before the end of 2007. Continuing the TOMS total ozone column data record that dates back to November 1978 is the primary OMI mission goal that is achievable with either OMI total ozone column data product.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of Ozone Monitoring Instrument total ozone column measurements using Brewer and Dobson spectrophotometer ground- based observations

[1] In this paper we present validation results of the total ozone column data products of the Ozone Monitoring Instrument (OMI) on board the NASA EOS-AURA satellite through comparisons with ground-based observations by Dobson and Brewer spectrophotometer instruments. Quality-controlled and archived total ozone column data from these ground-based instruments located at stations worldwide have b...

متن کامل

Validation of the Aura Ozone Monitoring Instrument total column ozone product

[1] This paper is an overview of the validation of the total column ozone data products from the Ozone Monitoring Instrument (OMI) on board the NASA EOS-Aura satellite. OMI is an imaging UV/visible spectrometer that maps global ozone on a daily basis. There are two ozone products from OMI, one derived using the traditional TOMS retrieval algorithm and another derived using a Differential Optica...

متن کامل

Validation of Omi Total Ozone Using Ground-based Brewer Observations

Near-to-real time as well as “archive quality” Brewer total ozone observations, which are performed with well maintained and calibrated instruments over the Northern Hemisphere have been used for the validation of the total ozone column product of the Ozone Monitoring Instrument (OMI) aboard the NASA EOS-Aura satellite. During the commissioning phase of OMI, the near-to-real time ground-based d...

متن کامل

Comparison of OMI ozone and UV irradiance data with ground-based measurements at two French sites

Ozone Monitoring Instrument (OMI), launched in July 2004, is dedicated to the monitoring of the Earth’s ozone, air quality and climate. OMI is the successor of the Total Ozone Mapping Spectrometer (TOMS) instruments and provides among other atmospheric and radiometric quantities the total column of ozone (TOC), the surface ultraviolet (UV) irradiance at several wavelengths, the erythemal dose r...

متن کامل

Evaluation of ozone total column measurements by the Ozone Monitoring Instrument using a data assimilation system

[1] On 15 July 2004, the Ozone Monitoring Instrument (OMI) on board the EOS Aura mission was launched. One of OMI’s priorities is to continue the record of high spatial resolution ozone total column measurements provided by the various Total Ozone Mapping Spectrometer (TOMS) instruments since 1978. To this end, it is essential to estimate the errors affecting OMI ozone total column measurements...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008