Outcome prediction in patients at high risk for coronary artery disease: comparison between 99mTc tetrofosmin and 99mTc sestamibi.

نویسندگان

  • Salvador Borges-Neto
  • Robert H Tuttle
  • Linda K Shaw
  • William T Smith
  • Diwakar Jain
  • R Edward Coleman
  • David Whellan
چکیده

PURPOSE To determine if there was any difference in the ability of physicians to predict prognosis with technetium 99m ((99m)Tc) sestamibi or (99m)Tc tetrofosmin in a large consecutive series of patients at high risk for coronary artery disease who underwent coronary angiography. MATERIALS AND METHODS This study included 1,818 consecutive patients who underwent a rest and stress single photon emission computed tomographic (SPECT) examination with either (99m)Tc sestamibi (n = 915) or (99m)Tc tetrofosmin (n = 903) and cardiac catheterization. A clinical index was generated and consisted of clinical and demographic variables. Information concerning death, cardiovascular death, and nonfatal myocardial infarction was 93% complete during the 1.5-year study period. Cox proportional hazards models were generated to help determine the incremental contribution of SPECT sum stress score (SSS) and the imaging agent variable to the clinical index. RESULTS Exercise was used for stress testing in 473 (52%) patients who received (99m)Tc tetrofosmin and 519 (57%) patients who received (99m)Tc sestamibi (P =.06). Cardiovascular death or myocardial infarction occurred in 130 patients. Resulting P values for chi(2) differences between models for the end points of (a) death from any cause, (b) cardiovascular death, and (c) cardiovascular death or myocardial infarction showed that SSS combined with clinical index was a significantly better model than adjusting for only baseline characteristics (P =.001, P <.001, P =.004, respectively). Incremental addition of either (99m)Tc tetrofosmin or (99m)Tc sestamibi to those models containing SSS and the clinical index did not show further significant improvement (P =.87, P =.88, and P =.26 for death from any cause, cardiovascular death, and cardiovascular death or myocardial infarction, respectively). CONCLUSION This study shows that the type of clinically available (99m)Tc-labeled myocardial perfusion agents should not affect interpretation of results for risk stratification and prognostic assessment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease.

UNLABELLED This study was designed to compare the tracer kinetics between 99mTc-sestamibi and 99mTc-tetrofosmin in a heterogeneous group of 24 patients admitted for routine perfusion imaging. METHODS Twelve patients were studied with 99mTc-tetrofosmin and 12 with 99mTc-sestamibi. In each group, six patients had a low likelihood for coronary artery disease, and six patients had angiographicall...

متن کامل

Myocardial uptake characteristics of three 99mTc-labeled tracers for myocardial perfusion imaging one hour after rest injection.

OBJECTIVE 99mTc-tetrofosmin and 99mTc-sestamibi are approved tracers for myocardial perfusion studies. Recently, a 99mTc-MIBI preparation from a different manufacturer (99mTc-cardiospect-MIBI) has been introduced to the market. Therefore, the aim of this study was the evaluation of 99mTc-tetrofosmin as well as of two different 99mTc-labeled MIBI tracers with regard to differences in imaging qua...

متن کامل

Evaluation of ِdiagnostic role of 99mTc-Tetrofosmin scintigraphy in cold thyroid nodules [Persian]

Introduction: Various radiopharmaceuticals, including 67Ga, 201Tl, and 99mTc-sestamibi have been used to differentiate benign from malignant thyroid nodules. 99mTc-Tetrofosmin, a lipophilic cationic radiotracer, and 99mTc-sestamibi have also been reported to accumulate in thyroid tumors. In this study, we evaluated the role of 99mTc-Tetrofosmin in the differentiation of malignant from ben...

متن کامل

Comparison of 99mTc-N-DBODC5 and 99mTc-MIBI of Myocardial Perfusion Imaging for Diagnosis of Coronary Artery Disease

Despite recent advances in therapeutic and diagnostic approaches, coronary artery disease (CAD) and its related cardiac disorders represent the most common cause of death in the United States. Nuclear myocardial perfusion imaging (MPI) technologies play a pivotal role in the diagnosis and treatment design for CAD. Recently, in order to develop improved MPI agents for diagnosis of CAD, (99m)Tc-[...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 232 1  شماره 

صفحات  -

تاریخ انتشار 2004